Data set: 1 m2 Alpha Sectional door Helix ALU with coating (00.01.000)

A more recent version of this data set exists in the database.

Most recent version of this data set:00.03.000
Other versions:00.02.000

Full name
1 m2 Alpha Sectional door Helix ALU with coating
Location
NL
Reference year
2017
Valid until
2022
Reference flow(s)
Type
EPD
Parameterized?
no
LCIA results included?
yes
Category
02 Building products / Doors, windows, shutters, and related products / Windows and doors
Synonyms
Use advice for data set
Scope: This Environmental Product Declaration (EPD) is valid for Alpha sectional doors of the type Helix. The production facilities are located in Didam (NL). The life cycle assessment is representative for the products introduced in the declaration for the given system boundaries. System boundary: Type of the EPD: cradle-to-gate. The production of the materials (steel, plastics, aluminiums, coating etc.) and also the motor-parts and other electronic components are modelled in A1. The transportation (road and sea) from the suppliers to Alpha deuren is modelled in A2. The assembly of the doors (energy use) and the packaging (including the production and transportation of the packaging materials) is modelled in A3. The generation of electricity and heat is modelled in A3.For the option coating is also the coating processes and the emissions of non-methane volatile organic compounds to air are modelled in A3. Production waste from A3 is modelled following the Dutch defaults for waste scenario’s (see 4.1.3). This modelling results in components for reuse, materials for recycling. The packaging materials (wood, cardboard and foil) can be exported for energy. According to EN 15804 (CEN 2013) the end-of-life system boundary of the construction product system is set where outputs of the system under study, e.g. materials, products or construction elements, have reached the end-of-waste state. Therefore, waste processing of the material flows (e.g. undergoing recovery or recycling processes) during any module of the product system (e.g. during the production stage, use stage or end-of-life stage) are included up to the system boundary of the respective module. For all phases A1-A3 also processing up to the end-of-waste state or disposal of final residues including any packaging not leaving the factory gate with the product, are included. There are no materials for energy recovery. The waste from packaging materials will be incinerated and will not go to a power station with a high thermal energy efficiency.
Data set use approval
General comment
Sectional doors, type Helix ALU, constructed from extruded aluminium sections with finger pinch protection fitted with 20 mm PMMA (polymethyl methacrylate) double glazing. The floor section is fitted with a 40 mm ISO panel, with a microline motif. The ALU panels are 40 mm thick and available in heights varying between 250 and 366 mm. The horizontal seal retaining profile on the top section is made from aluminium, or supplied with a spray-painted finish (optional). The Helix ALU sections can be combined with insulated, steel-skinned Helix ISO panels. Surface treatment The panels are supplied as standard with an anodised finish. They can also be painted in a RAL colour chosen by the customer. This option is covered in this EPD. Track systems are made of 1.7 mm thick, closed steel angle profiles fitted with roller tracks made of 1.7 mm thick galvanised steel. The door hardware is attached using electrolytically galvanised self-tapping screws with a knurled integral lock-washer. The rollers feature nylon wheels and an 11 mm galvanised steel shaft. The door leaf is unbalanced and hung on steel chain and cables with a safety factor of 6. Helix doors are power operated doors. Draft seals are fitted around the periphery of the door leaf: top, side and floor seals made from EPDM (ethylene propylene diene monomer rubber) seals between the panels made from EPDM Operators The Helix sectional door is supplied with an electric drive with frequency inverter. The drive is directly connected to the shaft. Safety emergency chain hoist and emergency drive disconnect up to operator height in the case of electric drives slack cable safety / chain tensioner finger pinch safety
LCI Method Principle
LCI Method Approaches
No records found.
Completeness of product model
No statement
Reviews
  • Accredited third party review by
License and access conditions
Copyright
yes
Owner of data set
Novoferm Nederland B.V.
Technical purpose
Alpha industrial sectional doors are used in private homes, agricultural buildings, industrial buildings and non-residential buildings. For the application and use the respective national provisions apply. The space-saving industrial sectional door can be fitted to both outdoor and indoor walls. The Helix ALU sectional door is assembled from 1 horizontally profiled microline bottom panel and 40 mm ALU panels with a working height of 366, 488, or 610 mm. When the door is opened, the sections slide back under the roof or run into a spiral. In addition to the standard lift track system, high lift, vertical lift, and roof following are available. The industrial sectional door complies with /EN13241-1/ (products without smoke control and fire resistant characteristics).
Input Products
No records found.
Co-Products
No records found.
Data set version
00.01.000
Time stamp (last saved)
2017-09-25T10:56:16.685
Data set format
ILCD Format 1.1
Other versions
Compliance systems
  • DIN EN 15804 (Overall compliance: Not defined)
  • ISO 14025 (Overall compliance: Not defined)
Tag
Data Set deregistration
Are you sure you want to deregister selected dataset?
Please enter the reason of deregistration and confirm.