| Key Data Set Information | |||
| Location | RER | ||
| Reference year | 2024 | ||
| Name |
| ||
| Use advice for data set | Scope: SentryGlas® produced in Holesov, Czech Republic. Primary data of SentryGlas® production corresponds to the reference year 2020. System boundary: The type of EPD is cradle-to-gate with options, modules C1–C4, and module D (A1–A3, C, D and additional module A5). In the following section, a detailed description of the specific system boundaries is given: Module A1 to A3: The product stage includes the provision of all materials, products and energy, as well as waste processing up to the end-of-waste state or disposal of final residues during the product stage. These modules consider the manufacturing of system components/raw materials, the transport to the production site and the production processes of the products under study. The impact of packaging materials is included. Module A5: Treatment and disposal of packaging material. Credits for potential avoided burdens due to energy substitution of electricity and thermal energy generation are declared in module D and affect only the rate of primary material (no secondary materials). Module C1 to C4: The end-of-life scenarios are as follows: C1 - Deconstruction/demolition: Dismantling is manual (no environmental burden). C2 - Transport to treatment/disposal site: Average transport distance from the demolition site to waste treatment is assumed as 50 km to the landfill. C3 - Waste processing for reuse, recovery or recycling: No waste processing (no environmental burden). C4 - Disposal: Ionoplast film is 100 % landfilled. Module D: For the thermal and electrical energy generated in Module A5 due to the thermal treatment of packaging and product waste, avoided burdens have been calculated by the inversion of the electricity grid mix and thermal energy from natural gas, using European datasets. | ||
| Technical purpose of product or process | SentryGlas® interlayers need to be laminated between two pieces of glass. This sandwich arrangement is called laminated safety glass according to EN ISO 14449. | ||
| Classification |
Class name
:
Hierarchy level
| ||
| General comment on data set | SentryGlas® films are safety interlayers used in laminated architectural safety glass. These SentryGlas® interlayers offer safety advantages by retaining dangerous shards in case of glass breakage. They are commonly used safety glass interlayers available worldwide. This EPD covers SentryGlas® produced in Holseov, Czech Republic. Product codes: SentryGlas®, SentryGlas® Xtra, SentryGlas® translucent white. For the use and application of the product, the respective national provisions at the place of use apply; in Germany, for example, the building codes of the federal states and the corresponding national specifications. | ||
| Copyright | Yes | ||
| Owner of data set | |||
| Quantitative reference | |||
| Reference flow(s) |
| ||
| Time representativeness | |||
| Data set valid until | 2029 | ||
| Technological representativeness | |||
| Technology description including background system | SentryGlas® films are tough, resilient safety interlayers used in laminated architectural safety glass. These SentryGlas® interlayers offer safety advantages by retaining dangerous shards in case of glass breakage. SentryGlas® films are tough, resilient safety interlayers used in laminated architectural safety glass. These SentryGlas® interlayers offer safety advantages by retaining dangerous shards in case of glass breakage. Technical data: For calculating the light, solar and heat parameters of glazing specifically containing films from the Trosifol® & SentryGlas(r) product range please go to: https://www.trosifol.com/winslt-tool/ Sound Control data can be found here: https://www.trosifol.com/soundlab-ai/ The following data are valid for SentryGlas(r). Other products data can be found in our laminator brochure: https://www.trosifol.com/de/salessupport/downloads/produktbroschueren/ Declared unit: This declaration refers to the declared unit of 1m of Ionoplast film. The grammage of the Ionoplast film is 0.7372 kg/m. | ||
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
| Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
| Commissioner and goal | |
| Commissioner of data set | |
| Data generator | |
| Data set generator / modeller | |
| Data entry by | |
| Time stamp (last saved) | 2024-03-12T00:00:00 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | f977cb10-791e-43e7-89e2-4ce5b4481dfd |
| Data set version | 00.06.000 |
| Registration authority | |
| Registration number | EPD-KUR-20230073-CBA2-EN |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |