Close Collapse all sections
Process Data set: Geryon Security Revolving Door (en) en de

Key Data Set Information
Location DE
Reference year 2024
Name
Geryon Security Revolving Door
Use advice for data set Scope: This Environmental Product Declaration refers to a specific Geryon Security Revolving Door (SRD-E01) covering the variants 120° and 180°. The products are manufactured at the dormakaba production facility in Bhl (Germany). Green electricity is being used at this production site. Data represents the year 2022. System boundary: Type of EPD: cradle to gate with options, modules C1–C4, and module D (A1–A3 + C + D and additional modules: A4 + A5 + B6) Production - Module A1-A3 The product stage includes: — A1, raw material extraction, processing and mechanical treatments, processing of secondary material input (e.g. recycling processes), — A2, transport to the manufacturer, — A3, manufacturing and assembly including provision of all materials, products and energy, as well as waste processing up to the end-of-waste state. Construction stage - Modules A4-A5 The construction process stage includes: — A4, transport to the building site; — A5, installation into the building; including provision of all materials, products and energy, as well as waste processing up to the end-of-waste state or disposal of final residues during the construction process stage. Use stage - Module B6 The use stage related to the operation of the building includes: — B6, operational energy use. The potential use of electricity from the grid is declared in module B6. End-of-life stage– Modules C1-C4 and D The end-of-life stage includes: — C1, de-construction, demolition: — C2, transport to waste processing; — C3, waste processing for reuse, recovery and/or recycling; — C4, disposal; including provision and all transport, provision of all materials, products and related energy and water use. Module D (Benefits and loads beyond the system boundary) includes: — D, recycling potentials, expressed as net impacts and benefits.
Technical purpose of product or process For secure entry to: Sensitive areas in administrative buildings, industrial premises, government agencies and ministries Banks and financial institutions Data and research centres Staff entrances at airports Nuclear power plants
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.6.02 Komponenten von Fenstern und Vorhangfassaden / Türen und Tore / Aluminium
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Electronic and physical Access Control Systems
General comment on data set Secure areas require a reliable system for identifying and separating authorized persons. As these areas are usually representative of the building, a secure but at the same time transparent access solution is preferred. Geryon Security Revolving Door Owing to the high transparency grade of the glass elements and a wide variety of colours for the metal parts, all models elegantly blend in with their surroundings. A sophisticated sensor system in compliance with the latest standards prevents users from being injured. Depending on the security requirements, the door may be equipped with a contact mat, scales or internal monitoring. Other variants are reinforced bullet- and burglar-resistant designs, which are certified according to standards RC2 and RC3 respectively. Options like a rotating unit with an emergency exit function or a night closure complete the product range.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 459.0 kg
Time representativeness
Data set valid until 2027
Technological representativeness
Technology description including background system Thanks to the high degree of transparency of the glass elements and the wide range of colours of the metal parts, all models blend elegantly into their surroundings. Sophisticated sensor technology in accordance with the latest standards prevents users from being injured. Depending on security requirements, the door can be fitted with a contact mat, a scale or internal monitoring. Other variants include reinforced bullet and burglar-resistant versions that are certified to RC2 and RC3 standards. Options such as a turn unit with emergency exit function or a night lock round off the product range. Technical data: Key elements and options of the Geryon Security Revolving Door: • Users cannot become stuck thanks to end point locking • Safety sensor system according to DIN EN 16005 • Standard version has IR sensor system • Versions with resistance classes RC2 and RC3 • All-glass units with underfloor drive • Option with approved emergency exit column • Option with in-built scales with weight limits or actual weight • Option with night closure • Option with optical separation using SRD Vision Following technical data apply for Geryon Security Revolving Door (SRD-E01): Declared unit: The declared unit is 1 piece of product: 459 kg

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 8682
  • 0.173
  • 48.33
  • 0
  • 8218
  • 0
  • 0.086
  • 17.31
  • 4.96
  • -6287
Input
  • 57.24
  • 0
  • -48
  • 0
  • 0
  • 0
  • 0
  • -9.242
  • 0
  • 0
Input
  • 8739
  • 0.173
  • 0.325
  • 0
  • 8218
  • 0
  • 0.086
  • 8.066
  • 4.96
  • -6287
Input
  • 2.614E+4
  • 55.06
  • 1.791
  • 0
  • 1.855E+4
  • 0
  • 27.26
  • 871.7
  • 37.89
  • -1.443E+4
Input
  • 840.6
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • -840.6
  • 0
  • 0
Input
  • 2.698E+4
  • 55.06
  • 1.791
  • 0
  • 1.855E+4
  • 0
  • 27.26
  • 31.09
  • 37.89
  • -1.443E+4
Input
  • 30.6
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 20.65
  • 0.0003111
  • 0.017
  • 0
  • 9.502
  • 0
  • 0.0001541
  • 0.166
  • 0.01
  • -11.42
Output
  • 0.00006367
  • 5.34E-9
  • 2.639E-9
  • 0
  • 0.000007676
  • 0
  • 2.644E-9
  • 1.177E-7
  • 5.774E-7
  • -0.0001295
Output
  • 423.9
  • 0.006
  • 0.178
  • 0
  • 13.16
  • 0
  • 0.003
  • 6.916
  • 190.5
  • -237.3
Output
  • 1.261
  • 0.00005909
  • 0.00009411
  • 0
  • 2.814
  • 0
  • 0.00002926
  • 0.001
  • 0.0004311
  • -1.501
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 242.4
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 8.58
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 15.56
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 2042
  • 4.058
  • 5.671
  • 0
  • 1.06E+3
  • 0
  • 2.01
  • 67.72
  • 2.904
  • -1048
  • -5.496
  • 0.179
  • 5.529
  • 0
  • 3.516
  • 0
  • 0.089
  • 1.192
  • 0.01
  • -2.993
  • 2047
  • 3.879
  • 0.142
  • 0
  • 1055
  • 0
  • 1.921
  • 66.53
  • 2.886
  • -1045
  • 0.9723
  • 0.00009231
  • 0.00009331
  • 0
  • 1.529
  • 0
  • 0.00004571
  • 0.004
  • 0.008
  • -0.194
  • 6.478E-9
  • 4.095E-16
  • 1.022E-15
  • 0
  • 2.32E-11
  • 0
  • 2.028E-16
  • 3.369E-14
  • 1.07E-14
  • -7.33E-9
  • 4.56
  • 0.003
  • 0.002
  • 0
  • 1.417
  • 0
  • 0.002
  • 0.008
  • 0.016
  • -1.663
  • 10.22
  • 0.004
  • 0.002
  • 0
  • 2.328
  • 0
  • 0.002
  • 0.012
  • 0.021
  • -3.891
  • 18.08
  • 0.014
  • 0.007
  • 0
  • 5.434
  • 0
  • 0.007
  • 0.055
  • 0.059
  • -5.557
  • 0.002214
  • 8.301E-7
  • 1.999E-7
  • 0
  • 0.003
  • 0
  • 4.111E-7
  • 0.000005371
  • 0.000004957
  • -0.0005496
  • 1.637
  • 0.001
  • 0.0005735
  • 0
  • 0.517
  • 0
  • 0.0006117
  • 0.003
  • 0.005
  • -0.515
  • 248.2
  • 0.008
  • 0.703
  • 0
  • 229.9
  • 0
  • 0.004
  • 6.926
  • 0.303
  • -60.15
  • 0.027
  • 1.163E-7
  • 1.614E-8
  • 0
  • 0.0003053
  • 0
  • 5.76E-8
  • 4.623E-7
  • 2.592E-7
  • -0.009
  • 2.696E+4
  • 55
  • 1.79
  • 0
  • 1.854E+4
  • 0
  • 27.24
  • 31.09
  • 37.87
  • -1.443E+4

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 0.000008508
  • 7.334E-10
  • 4.494E-11
  • 0
  • 2.191E-7
  • 0
  • 3.632E-10
  • 1.009E-9
  • 3.206E-9
  • -2.48E-7
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 0.00002587
  • 3.136E-8
  • 1.947E-9
  • 0
  • 0.000008071
  • 0
  • 1.553E-8
  • 1.017E-7
  • 3.534E-7
  • -0.000008194
Incidence of disease due to PM emissions (PM) 2
  • 0.00009696
  • 2.041E-8
  • 8.798E-9
  • 0
  • 0.00001953
  • 0
  • 1.011E-8
  • 1.519E-7
  • 2.563E-7
  • -0.00006174
Human exposure efficiency relative to U235 (IR) 1
  • 242.2
  • 0.008
  • 0.015
  • 0
  • 461.7
  • 0
  • 0.004
  • 0.105
  • 0.044
  • -301.2
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 1.419E+4
  • 38.99
  • 0.85
  • 0
  • 7931
  • 0
  • 19.31
  • 11.68
  • 21.64
  • -5142
Soil quality index (SQP) 2
  • 3063
  • 0.141
  • 0.475
  • 0
  • 5905
  • 0
  • 0.07
  • 9.305
  • 7.895
  • -492.9