Process Data set: Padlocks (en) en de

Key Data Set Information
Location RER
Reference year 2024
Name
Padlocks
Use advice for data set Scope: This ARGE EPD covers padlocks and padlock fittings operated by means of a key. They are used for securing buildings, both outside and inside. The reference product used to calculate the impact this product group has on the environment is a padlock composed primarily of steel, Zamak and brass. This product is the only one assessed for this EPD and serves as reference to cover all products within this family. This product has been determined in accordance with ARGE and the market share as the most representative product of the family. System boundary: Type of the EPD: "cradle to gate with options, with modules C1 – C4, and module D (A1-A3, C1-C3, D and additional modules)" The analysis of the product life cycle includes the production and transport of the raw materials, the manufacture of the product and the packaging materials which are declared in modules A1-A3. Losses during production are considered as waste and are sent for recycling. No recycling processes are taken into account except for transport and electricity consumption for grinding the metals. When recycled metals are used as raw material only their transformation process is taken into account and not the extraction of the raw material. A4 module represents the transport of the finished padlock to the installation site. There is nowaste associated with the installation of the product. The A5 module therefore represents only the disposal of the product packaging. The End-of-Life (EoL) stages are also considered. The transportation to the EoL disposal site is taken into account in module C2. Module C4 covers the disposal of the locks. Module C3 covers the recycling of the individual elements according to European averages, with the remaining waste divided between incineration and landfill. Such a mixed scenario is declared due to the complex material mix of the product and the dependency of the EoL-route on the EoL-route of the product the padlock has been integrated into. In practice, the end of life has been modelled as follows: when a material is sent for recycling, generic transport and electric consumption of a shredder is taken into account (corresponding to the process Grinding, metals). Only then, is the material considered to have attained the end-of-waste state. each type of waste is modelled as a transport to the treatment site with a distance of 30 km. Parts sent for recycling include electricity consumption (grinding) and a flow (Materials for recycling, unspecified).
Technical purpose of product or process Padlocks are used as a stand-alone product to secure doors and gates without the need for a locking mechanism integrated into the door or gate.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.4.01 Komponenten von Fenstern und Vorhangfassaden / Beschläge / Stahlbeschläge
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Building Hardware products
General comment on data set This ARGE EPD covers external locking devices, including the corresponding fittings, used to secure doors and gates to frames.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • gross density: 1.0 kg/m^3
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system The manufacture of a padlock normally takes place in 3 steps: 1. preparation of the components of the semi-finished product in the factory or at external manufacturers. 2. pre-assembly of the components (in the factory) 3. final assembly (on site at the factory) The individual parts of the product are assembled manually. Technical data: Ideally, products comply with a suitable technical specification. EN 12320:2021, Building hardware - Padlocks and padlock fittings - Requirements and test methods is an example of such a specification and some products will comply with this. The relevant grading structure is shown in the following table: Declared unit: The declared unit for all products covered by ARGE EPD is 1 kg (of product). Since individual products will rarely weigh exactly 1 kg it is necessary to establish the exact weight of the product and then use this as a correction factor to determine the true values for 1 kg of product in the tables (Section 5).

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 10.49
  • 0.139
  • -0.7084
  • 0
  • 0.003971
  • 0.01794
  • 0.0008673
  • -1.215
Input
  • 1.785
  • 0
  • -0.2147
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 12.27
  • 0.139
  • -0.923
  • 0
  • 0.003971
  • 0.01794
  • 0.0008673
  • -1.215
Input
  • 70.1
  • 9.889
  • 0.338
  • 0
  • 0.2826
  • 0.09549
  • 0.1333
  • -10.71
Input
  • 0.4504
  • 0
  • -0.2903
  • 0
  • 0
  • 0
  • -0.07987
  • 0
Input
  • 70.55
  • 9.889
  • 0.04765
  • 0
  • 0.2826
  • 0.09549
  • 0.05339
  • -10.71
Input
  • 0.3558
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.06377
  • 0.001049
  • 0.00005187
  • 0
  • 0.00002996
  • 0.00006094
  • 0.0001311
  • -0.007134
Output
  • 0.000315
  • 0.00002581
  • 2.149E-7
  • 0
  • 7.373E-7
  • 3.355E-8
  • 1.032E-7
  • -0.0001178
Output
  • 2.406
  • 0.5204
  • 0.003187
  • 0
  • 0.01487
  • 0.0003557
  • 0.2287
  • -0.5109
Output
  • 0.0005804
  • 0.000143
  • 6.174E-7
  • 0
  • 0.000004087
  • 0.000001272
  • 6.823E-7
  • -0.00002299
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.199
  • 0
  • 0.093
  • 0
  • 0
  • 0.6683
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0005742
  • 0
  • 0.03705
  • 0
  • 0
  • 0
  • 0.003386
  • 0
Output
  • 0.003804
  • 0
  • 0.2455
  • 0
  • 0
  • 0
  • 0.02243
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 5.143
  • 0.6523
  • 0.2323
  • 0
  • 0.01864
  • 0.004476
  • 0.008274
  • -1.129
  • -0.209
  • 0
  • 0.209
  • 0
  • 0
  • 0
  • 0
  • 0
  • 5.344
  • 0.652
  • 0.02328
  • 0
  • 0.01863
  • 0.004464
  • 0.008272
  • -1.128
  • 0.007413
  • 0.0002608
  • 0.000001244
  • 0
  • 0.00000745
  • 0.00001113
  • 0.000002099
  • -0.0009952
  • 3.422E-7
  • 1.511E-7
  • 6.907E-10
  • 0
  • 4.317E-9
  • 2.263E-10
  • 7.315E-10
  • -4.647E-8
  • 0.02084
  • 0.001576
  • 0.00001846
  • 0
  • 0.00004504
  • 0.000009318
  • 0.00002182
  • -0.005728
  • 0.0419
  • 0.001852
  • 0.00001717
  • 0
  • 0.0000529
  • 0.00002299
  • 0.00001923
  • -0.01129
  • 0.06488
  • 0.004101
  • 0.00006596
  • 0
  • 0.0001172
  • 0.00003407
  • 0.00007204
  • -0.0147
  • 0.0004099
  • 0.000004649
  • 2.962E-8
  • 0
  • 1.328E-7
  • 5.015E-7
  • 4.097E-8
  • -0.00007162
  • 0.006686
  • 0.000368
  • 0.000006109
  • 0
  • 0.00001051
  • 0.000002946
  • 0.000006835
  • -0.001204
  • 1.935
  • 0.03009
  • 0.0002999
  • 0
  • 0.0008597
  • 0.001056
  • -0.0005784
  • -0.2819
  • 0.0005677
  • 0.000002312
  • 1.138E-8
  • 0
  • 6.605E-8
  • 1.082E-8
  • 8.493E-9
  • -0.0002339
  • 70.27
  • 9.886
  • 0.04763
  • 0
  • 0.2824
  • 0.09457
  • 0.05337
  • -10.72

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 2.635E-8
  • 2.496E-10
  • 3.373E-12
  • 0
  • 7.13E-12
  • 1.272E-12
  • 6.497E-12
  • -1.427E-10
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 4.017E-7
  • 7.841E-9
  • 1.371E-10
  • 0
  • 2.24E-10
  • 4.132E-11
  • 5.962E-11
  • -8.064E-9
Incidence of disease due to PM emissions (PM) 2
  • 3.5E-7
  • 5.238E-8
  • 2.995E-10
  • 0
  • 1.497E-9
  • 6.144E-11
  • 5.655E-10
  • -7.264E-8
Human exposure efficiency relative to U235 (IR) 1
  • 0.3464
  • 0.04292
  • 0.0001879
  • 0
  • 0.001226
  • 0.0008616
  • 0.0002055
  • -0.01065
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 316.5
  • 7.759
  • 0.04494
  • 0
  • 0.2217
  • 0.0476
  • 0.1167
  • -92.79
Soil quality index (SQP) 2
  • 59.01
  • 6.89
  • 0.03027
  • 0
  • 0.1969
  • 0.01455
  • 0.0909
  • -5.783