Close Collapse all sections
Process Data set: Solenoid Locks SVx 6000 (en) en de

Key Data Set Information
Location GLO
Reference year 2024
Name
Solenoid Locks SVx 6000
Use advice for data set Scope: This Environmental Product Declaration refers to a specific solenoid lock (SVA 6000) manufactured by dormakaba. This EPD is also representing the variants of SVP 6000 locks. The production site is located in Ennepetal (Germany). Green electricity is being used at this production site. The data represents the year 2022. System boundary: The type of EPD is according to EN 15804: "cradle to gate with options, modules C1–C4, and module D". The following modules are declared: A1-A3, B6, C1-C4, D and additional modules: A4 + A5 Production - Module A1-A3 The product stage includes: — A1, raw material extraction, processing and mechanical treatments, processing of secondary material input (e.g. recycling processes), — A2, transport to the manufacturer, — A3, manufacturing and assembly including provision of all materials, products and energy, as well as waste processing up to the end-of waste state. Construction stage - Modules A4-A5 The construction process stage includes: — A4, transport to the building site; — A5, installation into the building; including provision of all materials, products and energy, as well as waste processing up to the end-of waste state or disposal of final residues during the construction process stage. Use stage - Module B6 The use stage related to the operation of the building includes: — B6, operational energy use End-of-life stage– Modules C1-C4 and D The end-of-life stage includes: — C1, de-construction, demolition: — C2, transport to waste processing; — C3, waste processing for reuse, recovery and/or recycling; — C4, disposal; including provision and all transport, provision of all materials, products and related energy and water use. Module D (Benefits and loads beyond the system boundary) includes: — D, recycling potentials, expressed as net impacts and benefits.
Technical purpose of product or process Solenoid locks are suitable for use in emergency exits and escape routes in compliance with EN 179 or on panic doors with a horizontal push bar in compliance with EN 1125.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.7.02 Komponenten von Fenstern und Vorhangfassaden / Antriebssysteme / elektrisch
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Building Hardware products
General comment on data set Self-locking emergency escape locks automatically lock doors after each closing whether mechanically or motor-controlled. The emergency escape function allows the door to be opened at any time in the exit direction by simply operating the lever handle. Mechanical opening from the outside remains possible at any time by unlocking the profile cylinder insert. SVP 6000 microswitch-monitored emergency-escape lock with automatic locking action and with divided follower, mechanical sequential control and signalling through integrated monitoring contact, automatically locks the doors after each closing cycle. The automatic deadbolt throw of 20 mm ensures that the door is always locked in accordance with property insurance requirements. Meanwhile, thanks to the added one-sided emergency escape function, the door can be opened at any time in the exit direction by simply operating the lever handle or it can be opened from the outside through a key or engageable external lever. SVP 6000 An electrically-monitored panic lock with a split follower for the electrical engagement/disengagement the outside handle and manipulation-protected detectors SVA 6000 Electrically monitored emergency-escape lock with split follower for the electrical engagement/ disengagement of the outside lever handle Status message for trip latch, bolt, cylinder locking and lever handle For the use and application of the product the respective national provisions at the place of use apply. The standards which can be applied are the following: EN 179 EN 1125 EN 12209 EN 14846 Restriction of Hazardous Substances (RoHS)
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 1.04 kg
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system The new generation of dormakaba SVP emergency escape locks is ideally suited for use in emergency exits and escape routes, as well as in fire and smoke doors. Any door can be safely protected with the emergency escape function and the self-locking action. Technical data: The solenoid locks have following technical properties: Declared unit: The declared unit is 1 piece of the product including packaging: SVx 6000.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 20.45
  • 0.0003873
  • 0.55
  • 476.1
  • 0
  • 0.0001729
  • 1.225
  • 0
  • -2.139
Input
  • 1.758
  • 0
  • -0.546
  • 0
  • 0
  • 0
  • -1.212
  • 0
  • 0
Input
  • 22.21
  • 0.0003873
  • 0.004
  • 476.1
  • 0
  • 0.0001729
  • 0.013
  • 0
  • -2.139
Input
  • 92.06
  • 0.123
  • 0.02
  • 1075
  • 0
  • 0.055
  • 0.679
  • 0
  • -23.79
Input
  • 0.617
  • 0
  • 0
  • 0
  • 0
  • 0
  • -0.617
  • 0
  • 0
Input
  • 92.67
  • 0.123
  • 0.02
  • 1075
  • 0
  • 0.055
  • 0.062
  • 0
  • -23.79
Input
  • 0.398
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.041
  • 6.947E-7
  • 0.0001883
  • 0.551
  • 0
  • 3.102E-7
  • 0.000566
  • 0
  • -0.015
Output
  • 7.356E-7
  • 1.192E-11
  • 3.002E-11
  • 4.447E-7
  • 0
  • 5.325E-12
  • 1.146E-10
  • 0
  • -6.574E-8
Output
  • 0.197
  • 0.00001257
  • 0.002
  • 0.762
  • 0
  • 0.000005613
  • 0.006
  • 0
  • -0.087
Output
  • 0.003399
  • 1.319E-7
  • 0.00000107
  • 0.163
  • 0
  • 5.892E-8
  • 0.000003106
  • 0
  • -0.000223
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.805
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.098
  • 0
  • 0
  • 0
  • 0.3636
  • 0
  • 0
Output
  • 0
  • 0
  • 0.177
  • 0
  • 0
  • 0
  • 0.7029
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 6.762
  • 0.009
  • 0.065
  • 61.4
  • 0
  • 0.004
  • 0.233
  • 0
  • -2.289
  • -0.2222
  • 0.0004003
  • 0.063
  • 0.204
  • 0
  • 0.0001788
  • 0.181
  • 0
  • 0.002
  • 6.98
  • 0.009
  • 0.002
  • 61.11
  • 0
  • 0.004
  • 0.052
  • 0
  • -2.289
  • 0.005339
  • 2.061E-7
  • 0.000001061
  • 0.089
  • 0
  • 9.205E-8
  • 0.000004551
  • 0
  • -0.002
  • 7.472E-11
  • 9.143E-19
  • 1.163E-17
  • 1.344E-12
  • 0
  • 4.083E-19
  • 4.724E-17
  • 0
  • -1.407E-15
  • 0.01845
  • 0.000007799
  • 0.00001729
  • 0.082
  • 0
  • 0.000003483
  • 0.00002874
  • 0
  • -0.008
  • 0.0426
  • 0.000008667
  • 0.00001807
  • 0.135
  • 0
  • 0.000003871
  • 0.00003508
  • 0
  • -0.019
  • 0.06712
  • 0.00003066
  • 0.00008132
  • 0.315
  • 0
  • 0.00001369
  • 0.0001641
  • 0
  • -0.027
  • 0.00001672
  • 1.854E-9
  • 2.274E-9
  • 0.0001632
  • 0
  • 8.278E-10
  • 7.289E-9
  • 0
  • -9.889E-7
  • 0.006161
  • 0.000002758
  • 0.000006523
  • 0.03
  • 0
  • 0.000001232
  • 0.00001053
  • 0
  • -0.003
  • 1.172
  • 0.00001697
  • 0.008
  • 13.32
  • 0
  • 0.000007578
  • 0.024
  • 0
  • -0.396
  • 0.0006978
  • 2.597E-10
  • 1.836E-10
  • 0.00001769
  • 0
  • 1.16E-10
  • 6.967E-10
  • 0
  • -0.0006819
  • 92.06
  • 0.123
  • 0.02
  • 1074
  • 0
  • 0.055
  • 0.062
  • 0
  • -23.73

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Operational energy use
B6
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 2.135E-7
  • 1.638E-12
  • 5.111E-13
  • 1.269E-8
  • 0
  • 7.313E-13
  • 1.883E-12
  • 0
  • -2.511E-9
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 1.089E-7
  • 7.003E-11
  • 2.215E-11
  • 4.676E-7
  • 0
  • 3.127E-11
  • 1.149E-10
  • 0
  • -1.425E-8
Incidence of disease due to PM emissions (PM) 2
  • 4.633E-7
  • 4.557E-11
  • 1.001E-10
  • 0.000001132
  • 0
  • 2.035E-11
  • 2.445E-10
  • 0
  • -1.984E-7
Human exposure efficiency relative to U235 (IR) 1
  • 0.35
  • 0.00001886
  • 0.0001656
  • 26.75
  • 0
  • 0.00000842
  • 0.0004331
  • 0
  • -0.028
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 47.66
  • 0.087
  • 0.01
  • 459.5
  • 0
  • 0.039
  • 0.026
  • 0
  • -7.214
Soil quality index (SQP) 2
  • 46.79
  • 0.0003156
  • 0.005
  • 342.1
  • 0
  • 0.000141
  • 0.018
  • 0
  • -1.635