Close Collapse all sections
Process Data set: MFT-FOX HT & MFT-FOX VT (en) en de

Key Data Set Information
Location GLO
Reference year 2024
Name
MFT-FOX HT & MFT-FOX VT
Use advice for data set Scope: This document relates to the MFT-FOX HT 320 L 11 as a representative product for the MFT-FOX T portfolio including FOX VT and FOX HT. FOX T products cover the same applications and are equal in material constitution and have been summarized in this EPD. FOX HT and FOX VT can be divided into two classes with 1 bracket size. FOX VT to be used for the vertical faade application, FOX HT for horizontal ones. Moreover, FOX HT 320 L 11 is chosen because it displays the highest weight of this product group, leading to the most conservative results. System boundary: Type of EPD: Cradle to factory gate with modules C1-C4 and D. The following information modules are defined as system boundaries in this study: Production stage (A1- A3): - A1, raw material extraction, - A2, transport to the manufacturer, - A3, production. End of life (C1- C4): - C1, dismantling/demolition, - C2, transport, - C3, waste treatment, - C4, disposal. Reuse, recovery and recycling potential (D) In order to accurately record the indicators and environmental impacts of the declared unit, a total of 8 information modules are considered. The information modules A1 to A3 describe the provision of materials, transport to the production site and the production processes of the product itself. The primary products are sourced from the European Union and Asia. Transport is by lorry and ship. The following flow charts illustrate the underlying production process. Figure Information modules A 1 to A3 of the product. Figure Information modules A 1 to A3 of the packaging. In the information modules C1 to C4, the deconstruction or demolition from the building, the transport to waste disposal, the waste treatment and disposal of the product are recorded. Furthermore, reuse, recovery and recycling potentials are reported in information module D.
Technical purpose of product or process MFT-FOX T items are developed to be fixed on base materials like concrete, masonry, steel frame structure and wood. This product is used as a substructure for ventilated faade (rainscreen) applications. According to the method of installation to the base material – anchors, screws or direct fastening can be used – with different hole geometries in the base plate. During the application the horizontal profiles are connected to the brackets with specially designed screws, which combine the fix and flexible point in one connection point. Due to thermal expansion of the profile, the brackets take over this movement. With this system, wall tolerances of up to 40 mm can be balanced.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 4.3.02 Metalle / Aluminium / Aluminiumprofil
  • IBUCategories: 02 Building products / Metallic products and ancillaries / Building metals
General comment on data set MFT-FOX T is designed as an aluminium substructure system. The brackets are suitable for all faade cladding. The products are used for fastening ventilated faade substructure to concrete, masonry, steel frame structure and wood. They enable mounting faade substructures on the primary structure as a helping hand bracket and can be used to install vertical and horizontal support rails.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • gross density: 2700.0 kg/m^3
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system MFT-FOX T is designed as an aluminium substructure system. The brackets are suitable for all façade claddings. The products are used for fastening ventilated façade substructures to concrete, masonry concrete, masonry, steel frame constructions and wood. They enable the installation of façade substructures on the primary structure of the primary structure and can be used for the installation of vertical and horizontal support rails. Technical data: Technical documentation according to EN 1090-3. Declared unit: The declared product here is an aluminium profile from HILTI AG with the designation MFT-FOX HT 320 L11 as a representative product from the MFT-FOX HT & MFT-FOX VT portfolio. It is the heaviest product with the additional screw in the portfolio. The declared unit refers to 1 kg of aluminium profile. The packaging, based on 1 kg of aluminium profile, is also included in the calculation at 0.031 kg. The following table shows the data of the declared unit.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 28.62
  • 0.177
  • 0.00705
  • 0.0468
  • 0
  • -23.6
Input
  • 0.47
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 29.09
  • 0.177
  • 0.00705
  • 0.0468
  • 0
  • -23.6
Input
  • 89.09
  • 1.29
  • 0.0999
  • 19.91
  • 0
  • -64.6
Input
  • 19.69
  • 0
  • 0
  • -19.69
  • 0
  • 0
Input
  • 108.8
  • 1.29
  • 0.0999
  • 0.216
  • 0
  • -64.6
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.07008
  • 0.000296
  • 0.00000777
  • 0.00302
  • -0.0552
  • -0.0552
Output
  • 9.593E-9
  • 7.48E-11
  • 3.7E-13
  • 3.59E-12
  • 0
  • -4.69E-9
Output
  • 1.325
  • 0.000284
  • 0.0000144
  • 0.00553
  • 0
  • -1.08
Output
  • 0.004008
  • 0.000201
  • 1.29E-7
  • 0.0000106
  • 0
  • -0.00431
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.289
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 2.97
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 5.28
  • 0
  • 0

IndicatorUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 6.57
  • 0.0588
  • 0.00739
  • 1.39
  • 0
  • -4.55
  • 0.00227
  • 0.0000292
  • 0
  • 0.0000236
  • 0
  • -0.0015
  • 6.569
  • 0.0587
  • 0.00742
  • 1.39
  • 0
  • -4.55
  • 0.001958
  • 0.00000537
  • 0.0000679
  • 0.0000206
  • 0
  • -0.00107
  • 9.214E-12
  • 5.77E-13
  • 6.42E-16
  • 7.01E-14
  • 0
  • -8.62E-12
  • 0.01207
  • 0.0000697
  • 0.00000757
  • 0.000102
  • 0
  • -0.00853
  • 0.02425
  • 0.0000894
  • 0.00000882
  • 0.000151
  • 0
  • -0.0186
  • 0.0423
  • 0.000266
  • 0.0000362
  • 0.000714
  • 0
  • -0.0308
  • 0.000004456
  • 5.8E-8
  • 2.67E-8
  • 2.43E-8
  • 0
  • -0.00000262
  • 0.003891
  • 0.0000252
  • 0.00000299
  • 0.0000349
  • 0
  • -0.00283
  • 0.7629
  • 0.00493
  • 0.0000845
  • 0.129
  • 0
  • -0.607
  • 0.00000513
  • 2.84E-9
  • 4.73E-10
  • 3.35E-9
  • 0
  • -0.00000417
  • 108.6
  • 1.29
  • 0.0997
  • 0.216
  • 0
  • -6.45

IndicatorUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Incidence of disease due to PM emissions (PM) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Human exposure efficiency relative to U235 (IR) 1
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for ecosystems (ETP-fw) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Soil quality index (SQP) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND