Close Collapse all sections
Process Data set: VELUX lining LSB (en) en de

Key Data Set Information
Location RER
Reference year 2024
Name
VELUX lining LSB
Use advice for data set Scope: Productline LSB - lining; manufactured by VELUX in Germany for sale in Europe. Declaration according to ISO 14025 and EN 15804 describing specific environmental performance of the construction product. System boundary: Type of EPD: Cradle to gate - with options. The following life cycle stages were considered: Production stage A1-A3: Consideration of the production of raw materials (plastic profile and steel) and their processing (estimated energy data: electrical energy from the national residual mix and thermal energy from natural gas); transport of major materials to the manufacturing site; assembly of semi-finished products to the final product; packaging material (including waste paper input for paper and cardboard). End-of-Life stage C1, C2, C3: C1: a manual demolition is assumed, resulting in indicator value "0". C2: For the transport to EoL by truck a distance of 50 km is assumed. C3: A scenario for the incineration of plastic in a waste incineration plant (WIP) is assumed; metals are assumed to be recycled. The EoL-Scenario does not assume waste to be disposed of on a landfill site. Module C4 is declared as"0". Benefits for the next product system D: Resulting electrical and thermal energy from the WIP, avoiding the generation of electricity and heat via fossil fuels, is considered. The amount of metals after the reduction due to the net-flow calculations is sent to a recycling process. The effort for recycling, as well as the benefit for the regained metals are declared in module D. Contribution of waste flows is considered in the modules where they occur.
Technical purpose of product or process Standard linings tobe used in roofs with a roof thickness of min 170 mm to max 530 mm.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.8.04 Komponenten von Fenstern und Vorhangfassaden / Fenster / Kunststofffenster
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Windows and doors
General comment on data set VELUX linings ensure an easy and quick connection of the roof window to the interior ceiling finish. They and their facings are assembled before being clicked into the window rebate in one piece from the inside and there is no need for further framing. The linings are made in white PVC, need no finishing treatment and are not sensitive to moisture. The white, semi-gloss surface and the white facings supplied ensure a harmonious connection from the roof window to most walls. The linings are available in all window sizes and generations sold after 1991. Installation angle: Linings can be installed in roof pitches from 15° to 90°.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • grammage: 12.56 kg/m^2
    • layer thickness: 0.0 m
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system The manufacturing at the VELUX site mainly covers processing steps of semi-finished materials purchased from suppliers like profiles and pre-fabricated films, foams and sheets. Technical data: The Declaration of Performance including relevant technical specifications and test methods/test standards can be downloaded from the website www.velux.com/ce-marking. Declared unit: The declared unit is one m related to a reference window, that the lining is installed in connection with. The declared unit is based on the representative product measuring 0.78m x 1.178m.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 170.9
  • 0
  • 0.04483
  • 8.527
  • 0
  • -39.51
Input
  • 6.568
  • 0
  • 0
  • -0.1247
  • 0
  • 0
Input
  • 177.5
  • 0
  • 0.04483
  • 8.402
  • 0
  • -39.51
Input
  • 700.4
  • 0
  • 0.6183
  • 280.6
  • 0
  • -141.6
Input
  • 253.9
  • 0
  • 0
  • -244.7
  • 0
  • 0
Input
  • 954.3
  • 0
  • 0.6183
  • 35.9
  • 0
  • -141.6
Input
  • 1.466
  • 0
  • 0
  • 0
  • 0
  • 0.2709
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.215
  • 0
  • 0.0000491
  • 0.06067
  • 0
  • -0.03943
Output
  • 0.00001621
  • 0
  • 1.915E-12
  • 1.288E-10
  • 0
  • -0.00004368
Output
  • 1.913
  • 0
  • 0.00009426
  • 9.513
  • 0
  • -0.01302
Output
  • 0.03284
  • 0
  • 0.000001157
  • 0.001008
  • 0
  • -0.01033
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0.2902
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 4.895
  • 0
  • 0
  • 34.28
  • 0
  • 0
Output
  • 8.862
  • 0
  • 0
  • 62.03
  • 0
  • 0

IndicatorUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 42.45
  • 0
  • 0.04844
  • 24.78
  • 0
  • -8.104
  • 0.0802
  • 0
  • 0.002013
  • 0.003912
  • 0
  • -0.03947
  • 42.33
  • 0
  • 0.04601
  • 24.78
  • 0
  • -8.063
  • 0.03537
  • 0
  • 0.0004188
  • 0.00171
  • 0
  • -0.001517
  • 2.827E-10
  • 0
  • 5.884E-15
  • 1.608E-11
  • 0
  • -5.685E-11
  • 0.09711
  • 0
  • 0.00008119
  • 0.004762
  • 0
  • -0.008953
  • 0.06773
  • 0
  • 0.00009082
  • 0.005208
  • 0
  • -0.01219
  • 0.2229
  • 0
  • 0.000427
  • 0.0225
  • 0
  • -0.03321
  • 0.0001376
  • 0
  • 1.653E-7
  • 0.0000047
  • 0
  • -0.00001235
  • 0.02064
  • 0
  • 0.00003748
  • 0.001674
  • 0
  • -0.003121
  • 3.46
  • 0
  • 0.0005464
  • 2.43
  • 0
  • -0.9126
  • 0.00002378
  • 0
  • 2.978E-9
  • 1.415E-7
  • 0
  • -0.000001964
  • 953.6
  • 0
  • 0.616
  • 35.89
  • 0
  • -141.6

IndicatorUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 2.508E-7
  • 0
  • 8.955E-12
  • 9.917E-10
  • 0
  • -7.441E-9
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 4.87E-7
  • 0
  • 5.052E-10
  • 9.44E-8
  • 0
  • -5.366E-8
Incidence of disease due to PM emissions (PM) 2
  • 6.896E-7
  • 0
  • 5.868E-10
  • 1.128E-7
  • 0
  • -1.39E-7
Human exposure efficiency relative to U235 (IR) 1
  • 4.882
  • 0
  • 0.0001726
  • 0.1228
  • 0
  • -1.709
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 463.1
  • 0
  • 0.4375
  • 23.43
  • 0
  • -32.25
Soil quality index (SQP) 2
  • 276.1
  • 0
  • 0.2574
  • 7.699
  • 0
  • -26.14