Process Data set: Safe Lock Auditcon (en) en de

Key Data Set Information
Location GLO
Reference year 2024
Name
Safe Lock Auditcon
Use advice for data set Scope: This Environmental Product Declaration refers to a specific safe lock Auditcon manufactured by dormakaba. The production site is located in Nogales (Mexico). The data represents the year 2024. System boundary: The type of EPD is: cradle to gate with options, modules C1–C4, and module D (A1–A3 + C + D and additional modules: A4+ A5) Production - Module A1-A3 The product stage includes: — A1, raw material extraction, processing and mechanical treatments, processing of secondary material input (e.g. recycling processes), — A2, transport to the manufacturer, — A3, manufacturing and assembly including provision of all materials, products and energy, as well as waste processing up to the end-of-waste state. Construction stage - Modules A4-A5 The construction process stage includes: — A4, transport to the building site; — A5, installation into the building; including provision of all materials, products and energy, as well as waste processing up to the end-of-waste state or disposal of final residues during the construction process stage. End-of-life stage– Modules C1-C4 and D The end-of-life stage includes: — C1, de-construction, demolition: — C2, transport to waste processing; — C3, waste processing for reuse, recovery and/or recycling; — C4, disposal; including provision and all transport, provision of all materials, products and related energy and water use. Module D (Benefits and loads beyond the system boundary) includes: — D, recycling potentials, expressed as net impacts and benefits.
Technical purpose of product or process The Auditcon family of electronic locks addresses the security requirements of a broad range of financial, retail, commercial and industrial markets.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.7.02 Komponenten von Fenstern und Vorhangfassaden / Antriebssysteme / elektrisch
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Electronic and physical Access Control Systems
General comment on data set The safe lock series Audicon protects from unauthorized access. The series is totally self-powered, using the PowerStar Technology. Auditcon offers the advantages and convenience of true stand-alone electronic safe access. It was developed to address the security requirements of a broad range of retail, commercial and industrial markets. For the safe lock Auditcon the standards which can be applied are the following: VDS 2344 VDS 2396 EN 1300 UL 2058 2011/65/EU (RoHS) The CE marking takes into account the proof of conformity with the respective harmonised standards based on the legal provisions above.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 0.949 kg
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system The Audicon safe lock series protects against unauthorised access. The series is fully self-powered and utilises PowerStar technology. Audicon offers the advantages and convenience of a genuine, stand-alone electronic safe access. It is designed to meet the security requirements of a wide range of retail, commercial and industrial markets. Technical data: The safe lock Auditcon has following technical properties:

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 14.01
  • 0.0003547
  • 1.619
  • 0
  • 0.0001592
  • 0.851
  • 0.002
  • -3.02
Input
  • 2.331
  • 0
  • -1.608
  • 0
  • 0
  • -0.723
  • 0
  • 0
Input
  • 16.34
  • 0.0003547
  • 0.011
  • 0
  • 0.0001592
  • 0.128
  • 0.002
  • -3.02
Input
  • 64.96
  • 0.113
  • 0.08
  • 0
  • 0.051
  • 16.31
  • 0.014
  • -15.89
Input
  • 15.83
  • 0
  • -0.02
  • 0
  • 0
  • -15.81
  • 0
  • 0
Input
  • 80.79
  • 0.113
  • 0.061
  • 0
  • 0.051
  • 0.5
  • 0.014
  • -15.89
Input
  • 0.128
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.02901
  • 6.363E-7
  • 0.0005574
  • 0
  • 2.856E-7
  • 0.003
  • 0.0000035
  • -0.005
Output
  • 0.000001745
  • 1.092E-11
  • 9.044E-11
  • 0
  • 4.902E-12
  • 1.83E-9
  • 2.116E-10
  • -2.16E-7
Output
  • 0.2062
  • 0.00001151
  • 0.006
  • 0
  • 0.000005167
  • 0.107
  • 0.07
  • 0.016
Output
  • 0.002063
  • 1.209E-7
  • 0.000003173
  • 0
  • 5.424E-8
  • 0.00001901
  • 1.58E-7
  • -0.0009418
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.318
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.29
  • 0
  • 0
  • 2.11
  • 0
  • 0
Output
  • 0
  • 0
  • 0.526
  • 0
  • 0
  • 4.767
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 5.034
  • 0.008
  • 0.191
  • 0
  • 0.004
  • 1.136
  • 0.001
  • -1.044
  • -0.214
  • 0.0003667
  • 0.185
  • 0
  • 0.0001646
  • 0.108
  • 0.000003615
  • -0.002
  • 5.243
  • 0.008
  • 0.006
  • 0
  • 0.004
  • 1.028
  • 0.001
  • -1.041
  • 0.005277
  • 1.888E-7
  • 0.000003191
  • 0
  • 8.473E-8
  • 0.00005909
  • 0.000003044
  • -0.0006413
  • 2.087E-10
  • 8.375E-19
  • 3.482E-17
  • 0
  • 3.758E-19
  • 5.311E-16
  • 3.922E-18
  • -2.713E-14
  • 0.01671
  • 0.000007144
  • 0.00005105
  • 0
  • 0.000003206
  • 0.0001279
  • 0.000005914
  • -0.002
  • 0.03795
  • 0.000007939
  • 0.00005341
  • 0
  • 0.000003563
  • 0.0001984
  • 0.000007588
  • -0.003
  • 0.06
  • 0.00002809
  • 0.0002404
  • 0
  • 0.0000126
  • 0.0009064
  • 0.00002146
  • -0.005
  • 0.0000215
  • 1.698E-9
  • 6.79E-9
  • 0
  • 7.619E-10
  • 8.456E-8
  • 1.817E-9
  • -0.000001813
  • 0.005656
  • 0.000002527
  • 0.00001926
  • 0
  • 0.000001134
  • 0.00004631
  • 0.000001953
  • -0.0005112
  • 1.067
  • 0.00001555
  • 0.024
  • 0
  • 0.000006976
  • 0.116
  • 0.0001109
  • -0.14
  • 0.002
  • 2.379E-10
  • 5.488E-10
  • 0
  • 1.068E-10
  • 7.313E-9
  • 9.5E-11
  • -0.0001772
  • 80.77
  • 0.113
  • 0.061
  • 0
  • 0.05
  • 0.499
  • 0.014
  • -15.88

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 3.669E-9
  • 1.5E-12
  • 1.523E-12
  • 0
  • 6.731E-13
  • 1.614E-11
  • 1.175E-12
  • 1.372E-9
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 1.255E-7
  • 6.415E-11
  • 6.7E-11
  • 0
  • 2.879E-11
  • 1.589E-9
  • 1.295E-10
  • 1.649E-7
Incidence of disease due to PM emissions (PM) 2
  • 3.455E-7
  • 4.174E-11
  • 2.974E-10
  • 0
  • 1.873E-11
  • 2.411E-9
  • 9.394E-11
  • -3.452E-8
Human exposure efficiency relative to U235 (IR) 1
  • 0.1793
  • 0.00001727
  • 0.0004896
  • 0
  • 0.000007751
  • 0.002
  • 0.00001626
  • -0.141
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 57.83
  • 0.08
  • 0.029
  • 0
  • 0.036
  • 0.189
  • 0.008
  • -4.249
Soil quality index (SQP) 2
  • 46.78
  • 0.0002891
  • 0.016
  • 0
  • 0.0001298
  • 0.149
  • 0.003
  • -1.808