| Key Data Set Information | |||
| Location | RER | ||
| Reference year | 2024 | ||
| Name |
| ||
| Use advice for data set | Scope: The environmental product declaration refers to a single leaf door type Jansen Art'15 in specific dimension width x height. The characteristic values used for the system components Art'15 in the LCA are provided by Jansen AG. The declared product is defined according to the profile series and product characteristics. The location of the production site is Oberriet/ Switzerland. This EPD was created with the help of a semi-automatic LCA-Tool. System boundary: Type of EPD according to EN 15804: "cradle to gate with options, modules C1–C4, and module D". The following modules are declared: A1–A3, C, D and additional modules: A4, A5 Production (modules A1-A3): This module considers the provision of all relevant door components (i.e. metal profiles/components, plastic parts/profiles and glazing) and raw materials including their transport to the declared production plant. This considers the manufacturing and assembly of these components, including waste processing up to the end-of-waste state. The impact of packaging materials is also covered by this module. Transport to the construction site (module A4): A distance of 100 km is considered for the transport of the packed finished product via truck. The transport distance can be modified project-specific if required by linear scaling. Installation (module A5): Treatment and disposal of packaging material is considered in this module. Credits for potential avoided burdens due to energy substitution of electricity and thermal energy generation are declared in module D under European conditions and affects only the rate of primary materials (no secondary materials). EoL stage (modules C1-C4): Module C1 - considers manual deconstruction (without environmental burdens). Module C2 - considers 50 km truck transport to waste processing. The transport distance can be modified project-specific if required by linear scaling. Modules C3 and C4 - consider waste processing and/or disposal with the following scenarios: Scenario 0: 100% thermal treatment of all raw materials with heating value including plastic system parts and 100% recycling of metal system components (C3). Landfill of all materials without heating value (except metals) including glazing (C4). For mineral based components (i.e. gypsum board), construction waste processing (shredding) and material recycling as filling material (incl. benefits for substitution of gravel in Module (D) is considered, assuming 3% recycling losses are sent to landfill (C4). Scenario 1 (module C3/1): 100% recycling of plastic system parts (excluding e-waste sent to incineration) and 100% recycling of metal system components. Landfill of all materials without heating value (except metals) including glazing (C4/1). For mineral based components (i.e. gypsum board), construction waste processing (shredding) and material recycling as filling material (incl. benefits for substitution of gravel in Module D/1) are considered, assuming 3% recycling losses are sent to landfill (C4/1). Modules C4 & C4/1 are identical. Benefits and loads beyond the product system boundary (module D): Considers credits and loads from the recycling of the metal components and mineral based components (i.e. gypsum board) as filling material (incl. benefits for the substitution of gravel (duplicated in D and D/1) and the recycling of the plastic system parts/profiles (D/1). Avoided burdens from the thermal treatment of all raw materials with heating value (including plastic system parts/profiles) (D) and packaging treatment (duplicated in D and D/1) under European conditions are considered. This affects only the rate of primary materials (no secondary materials). | ||
| Technical purpose of product or process | The Jansen Art'15 door can be integrated for building ventilation and light transmission and it meets all the requirements of an interior or exterior wall without taking over load-bearing functions. | ||
| Classification |
Class name
:
Hierarchy level
| ||
| General comment on data set | Jansen Art'15 door, with a basic depth of 50 mm, is a non-insulated steel profile system that offers a distinctive design. The steel material guarantees a long lifespan. As a result, the Jansen Art'15 meets the demanding design requirements of ambitious architects and the high expectations of discerning clients in terms of both design and functionality. The extremely narrow and robust steel profile system ensures durable, highly stable constructions within an exceptionally slim frame. | ||
| Scenarios |
| ||
| Copyright | Yes | ||
| Owner of data set | |||
| Quantitative reference | |||
| Reference flow(s) |
| ||
| Time representativeness | |||
| Data set valid until | 2029 | ||
| Technological representativeness | |||
| Technology description including background system | The main material for our profiles is steel. Description of life cycle stages modeled: Modules A1-A3: Our steel profile system consists of the following materials: glazing (single-pane safety glass), thermally separated steel profile (fire-resisting profiles), aluminium and stainless steel accessories as well as gaskets made of CR and EPDM. Module A4: A truck transport to the building site at a distance of 100 kilometers was considered (truck, 40 tons EURO6). The transport distance will be adjusted at the building level. Module A5: For the construction, it is assumed that the window is installed manually (load-free). Module C1: For deconstruction, it is considered that the window is deconstructed manually. Module C2: For the transport from the building site to the landfill 50 km (truck, 40 tons EURO6) were assumed. Module C3: Recycling is accounted for all metal components. Thermal treatment is accounted for all plastic components. Module C4: Landfill is considered of all materials without heating material. Module D: Metals are assumed to be recycled. Technical data: According to the CE marking, the following structural data for the element must be stated: Declared unit: The declared unit is a 1 m2 of Jansen Art'15 door element. The actual reference size of the declared door element has dimensions of 1230 mm x 2180 mm. | ||
| Subtype | specific dataset | ||||
| LCA methodology report | |||||
| Data sources, treatment and representativeness | |||||
| Documentation of data quality management | |||||
| Data source(s) used for this data set | |||||
| Completeness | |||||
| Validation | |||||
| |||||
| Compliance Declarations | |||||
| Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
| Compliance |
Compliance system name
|
Approval of overall compliance
|
Nomenclature compliance
|
Methodological compliance
|
Review compliance
|
Documentation compliance
|
Quality compliance
|
| Commissioner and goal | |
| Commissioner of data set | |
| Data generator | |
| Data set generator / modeller | |
| Data entry by | |
| Time stamp (last saved) | 2024-11-29T00:00:00 |
| Data set format(s) | |
| Publication and ownership | |
| UUID | 8476b2c2-29dd-4706-a067-f2dd4caec09e |
| Data set version | 00.02.100 |
| Registration authority | |
| Registration number | EPD-JAN-20240298-CBA1-EN |
| Owner of data set | |
| Copyright | Yes |
| License type | Free of charge for all users and uses |
| Access and use restrictions | None |