Close Collapse all sections
Process Data set: ROCKWOOL stone wool insulation (medium bulk density range) (en) en de

Key Data Set Information
Location DE
Reference year 2024
Name
ROCKWOOL stone wool insulation (medium bulk density range)
Use advice for data set Scope: This Environmental Product Declaration refers to a declared unit of 1 m unfaced or uncoated, resin-bonded stone wool from ROCKWOOL in the medium bulk density range (60-120 kg/m). It is produced at the sites in Gladbeck, Neuburg and Flechtingen (Germany) for which the production data for the year 2022 were collected and weighted according to the mass-based production quantity. The declared average considers the total amount of stone wool in the defined bulk density range produced at the three sites. The averaging results in an average bulk density of 99 kg/m for stone wool insulations in the medium bulk density range. The environmental impacts of the facings can be found in appendix 1. The life cycle assessment therefore represents 100 % of the stone wool produced by ROCKWOOL. The products represented by this EPD are listed in appendix 2. System boundary: The life cycle assessment of stone wool insulation material includes a cradle-to-gate analysis of the products environmental impacts with the modules C1-C4 and module D (A1-A3 + C + D). Subsequent life cycle phases are part of the analysis: Module A1–A3 | Production stage The production stage includes the upstream burdens of raw material supply (basalt, dolomite, sand, secondary raw materials, binding agents, etc.), and of energy carriers, the respective transports to the ROCKWOOL sites. The system boundary for secondary raw materials used in production is set after the end of waste status has been reached. The system boundary for secondary raw materials is defined according to EN 15804. During production, melting in the melting furnace, fiberization, injection of binder, compacting, curing, cutting and packaging of the stone wool are considered. The manufacturing process is modelled based on the primary data of all sites considered. The production of the facings of stone wool products is declared in a separate appendix to the EPD. Module A4 | Transport to construction site The transport from the plants to the customer is considered as a weighted average based on a representative scenario (350 km truck transport). Module A5 | Assembly For installation in the building, a scenario of 2 % waste is declared according to EURIMA (2019). The losses during installation are highly dependent on the building geometry and the specific application. Thus, the percentage of waste can vary greatly in the building context and must be adjusted at the building level according to the actual conditions. In addition to the losses during installation, module A5 includes the environmental impacts from the processing of the packaging of the products. Module C1 | Deconstruction and demolition For the disassembly of the stone wool products, a manual dismantling was assumed. Referring energy demand is considered to be negligible. Module C2 | Transport to disposal Module C2 includes the transport to waste treatment. In this case, transport by truck over a transport distance of 50 km is assumed. This corresponds to the recommendations according to EURIMA (2019). Module C3 | Waste processing The declared scenario assumes landfilling of the stone wool, therefore no environmental impacts from the waste treatment of the products are declared in C3. Module C4 | Disposal Module C4 refers to the emissions from the disposal of the insulation material. The chosen scenario, therefore, includes the environmental burdens of landfilling of the product. The biogenic carbon in the binder of the products is treated as emissions of biogenic CO2 from the technosphere into the natural environment. Module D | Benefits and loads beyond the system boundary In module D the substitution potential from the energy recovery of the packaging is declared.
Technical purpose of product or process Stone wool insulation materials are used in buildings and industrial plants for thermal insulation as well as noise and fire protection. The main application areas of the products declared in this EPD are: - All areas of application according to DIN 4108-10 for wall, ceiling and roof applications with the specified requirements regarding thermal and sound insulation and the mechanical properties - Blowing wool and loose-fill insulation - Technical insulation and building services (e.g. insulation of pipes for ventilation, heating and hot water, district heating pipelines, boilers and equipment) - Fire protection elements and industrial applications (e.g. air-conditioning ducts, fire protection doors, prefabricated components, chimney systems, cable penetration sealing)
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 2.1.03 Dämmstoffe / Mineralwolle / Steinwolle
  • IBUCategories: 02 Bauprodukte / Wärmedämmungsprodukte / Mineralische Dämmstoffe
General comment on data set Stone wool is a non-combustible insulating material consisting mainly of amorphous fibres obtained from a silicate melt. The stone wool insulation materials described in this declaration are produced in the form of rolls, boards, mats, lamella mats, pipe sections, moulded parts as well as loose-fill insulation and blowing wool in the medium bulk density range (60-120 kg/m). The ready-made products are supplied in thicknesses between 10 mm and 400 mm. For certain applications, the insulation materials are provided with a functional facing or coating on one or both sides. The environmental effects of the facings and coatings are shown in appendix 1 on the basis of 1 m.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • gross density: 24.0 kg/m^3
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system For production, the required quantities of the raw materials are weighed, mixed and fed into a melting unit. The raw materials are melted at temperatures of approx. 1,400-1,500 °C. A jet of the molten liquid then hits rapidly rotating metal rollers and is spun into fibres. To ensure dimensional stability, dust reduction and hydrophobisation, the fibres are sprayed with an aqueous solution of binder, mineral oil and bonding agent and then placed on conveyor belts under negative pressure. Optionally, laminations or coatings can then be applied. (The corresponding environmental impacts are listed in Appendix 1). The binder is cured above 200 °C in a continuous curing oven. The structure and density of the product can thereby be adapted to the exact application requirements. The stone wool is cut to the desired size and shape. The finished products are packaged and prepared for despatch. Any stone wool left over from the production process is fed back into the production process. Quality assurance: - all products according to RAL-GZ 388 - Factory production control and third-party monitoring in accordance with European regulations - KEYMARK according to Insulation KEYMARK Scheme Rules 2.1; for technical insulation according to VDI 2055 according to KEYMARK Scheme Rules and AGI-Q 132 - EUCEB - Quality management system according to EN ISO 9001 Declared unit: This EPD refers to a declared unit of 1 m unfaced stone wool insulation material with a declared bulk density of 99 kg/m (medium bulk density range 60-120 kg/m).

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 59.55
  • 2.468
  • 31.51
  • 0
  • 0.3526
  • 0
  • 3.219
  • -7.86
Input
  • 52.94
  • 0
  • -28.93
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 112.5
  • 2.468
  • 2.573
  • 0
  • 0.3526
  • 0
  • 3.219
  • -7.86
Input
  • 1245
  • 34.04
  • 50.28
  • 0
  • 4.863
  • 0
  • 19.78
  • -26.9
Input
  • 117.9
  • 0
  • -21.03
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 1363
  • 34.04
  • 29.26
  • 0
  • 4.863
  • 0
  • 19.78
  • -26.9
Input
  • 9.532
  • 0
  • 0.1906
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.2762
  • 0.002703
  • 0.01553
  • 0
  • 0.0003862
  • 0
  • 0.004992
  • -0.006368
Output
  • 1.893E-7
  • 1.054E-10
  • 3.816E-9
  • 0
  • 1.506E-11
  • 0
  • 4.306E-10
  • -1.418E-9
Output
  • 8.554
  • 0.005189
  • 2.203
  • 0
  • 0.0007413
  • 0
  • 98.9
  • -0.01331
Output
  • 0.0391
  • 0.00006371
  • 0.000834
  • 0
  • 0.000009101
  • 0
  • 0.0002251
  • -0.002086
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.1972
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 6.941
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 12.42
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 115.4
  • 2.49
  • 6.825
  • 0
  • 0.3557
  • 0
  • 3.235
  • -1.462
  • -2.484
  • 0.005631
  • 2.649
  • 0
  • 0.0008044
  • 0
  • 1.768
  • -0.006681
  • 117.9
  • 2.461
  • 4.175
  • 0
  • 0.3516
  • 0
  • 1.463
  • -1.455
  • 0.04019
  • 0.02306
  • 0.001447
  • 0
  • 0.003294
  • 0
  • 0.004611
  • -0.0000952
  • 1.271E-10
  • 3.239E-13
  • 2.942E-12
  • 0
  • 4.628E-14
  • 0
  • 3.773E-12
  • -1.151E-11
  • 0.2636
  • 0.00447
  • 0.005954
  • 0
  • 0.0006386
  • 0
  • 0.008208
  • -0.001486
  • 0.8148
  • 0.004999
  • 0.01718
  • 0
  • 0.0007143
  • 0
  • 0.01053
  • -0.001827
  • 2.345
  • 0.0235
  • 0.05047
  • 0
  • 0.003358
  • 0
  • 0.02993
  • -0.005711
  • 0.0005706
  • 0.000009102
  • 0.00001177
  • 0
  • 0.0000013
  • 0
  • 0.000002988
  • -0.000002374
  • 0.08689
  • 0.002063
  • 0.001988
  • 0
  • 0.0002948
  • 0
  • 0.00272
  • -0.0005335
  • 1.386
  • 0.03008
  • 0.4507
  • 0
  • 0.004298
  • 0
  • 0.1629
  • -0.1395
  • 0.00001941
  • 1.651E-7
  • 3.963E-7
  • 0
  • 2.358E-8
  • 0
  • 6.859E-8
  • -1.051E-7
  • 1362
  • 33.91
  • 29.24
  • 0
  • 4.845
  • 0
  • 19.75
  • -26.9

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Incidence of disease due to PM emissions (PM) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Human exposure efficiency relative to U235 (IR) 1
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for ecosystems (ETP-fw) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Soil quality index (SQP) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND