Close Collapse all sections
Process Data set: Rhenofol CV, Rhenofol CG (en) en de

Key Data Set Information
Location DE
Reference year 2024
Name
Rhenofol CV, Rhenofol CG
Use advice for data set Scope: This Environmental Product Declaration refers to the following products manufactured by FDT Flachdach Technologie GmbH at its Mannheim plant: Rhenofol CG 1.2 mm / 1.5 mm / 1.8 mm / 2.0 mm Rhenofol CV 1.2 mm / 1.5 mm / 1.8 mm / 2.0 mm The LCA results listed in this EPD represent an average of the two products Rhenofol CV and Rhenofol CG, and refer to a thickness of 1.5 mm. Averaging is based on the corresponding production volumes (by area produced). The EPD covers the production of the roofing membrane, the transport of the product to the construction site, the installation of the roofing membrane, the incineration, and the ensuing benefits for the next product system. The LCA results listed in this EPD refer to a thickness of 1.5 mm. Using the formula in Section 5, all results can be converted to other thicknesses. System boundary: The EPD type is in accordance with EN 15804+A2. This is an EPD from the cradle to the factory gate with options, Modules C1-C4 and Module D (A1-A3 + C + D and additional Modules A4 and A5). The individual life cycle stages are described below. Modules A1-A3 The product stage comprises Modules A1 (production and upstream chains of the raw materials used), A2 (transport to the production site), and A3 (energy and waste flows and packaging materials). Modules A4-A5 These modules include the transport to the construction site (A4) and utilisation of the packaging material (A5). Module C1: In this module, the manual dismantling of the roofing membranes is declared so that the associated environmental impacts are not relevant. Module C2 This module declares the transport of the used roofing membranes for waste management at the end of product life. Module C3 This module includes the thermal utilisation (100%) of the roofing membranes in a waste incineration plant (MVA) with an R1 value > 0.6. Module C4 Landfilling is not of relevance for the roofing membranes. Module D The potential benefits for the next product system are declared in this module. In addition, potential credits from the utilisation of packaging from Module A5 are indicated.
Technical purpose of product or process Rhenofol CV is used for sealing purposes on flat and inclined roofs in mechanically-fastened layers. Rhenofol CG is suitable for sealing green, gravel-ballasted or used roofs. The roofing membranes are also used as damp-proof sheets (type A) and as tanking sheets (type T). The manufacturers installation instructions must be observed during processing.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 6.3.02 Kunststoffe / Dachbahnen / PVC-Dachbahnen
  • IBUCategories: 02 Bauprodukte / Abdichtungen / Dach- und Dichtungsbahnsysteme aus Kunststoffen und Elastomeren
General comment on data set Rhenofol CV and Rhenofol CG are multi-layer plastic roofing and waterproofing membranes based on polyvinyl chloride (PVC-P), available in various colours and designs: Rhenofol CV: Rhenofol CV (1.2 mm / 1.5 mm / 1.8 mm / 2.0 mm) has an internal layer of synthetic fibres as reinforcement (application type: DE/E1 PVC-P-NB-V-PG). Seams are joined by hot air or solvent welding agent.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • layer thickness: 0.0015 m
    • grammage: 1.94 kg/m^2
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system The PVC mixture for Rhenofol CV and Rhenofol CG is produced via a dry blend. After homogenisation and jellifying in the heating mixer, the mixture is added to the cooling mixer from where it is plastified with an extruder and mixing roll and shaped as foil using calendar technology. A doubling calender is used to finish the roofing membrane with an internal reinforcement layer (Rhenofol CV) or an insert of glass fleece (Rhenofol CG). Production is subject to continuous measurement of product quality as part of the implemented quality management system in accordance with ISO 9001 and the energy management system in accordance with ISO 50001. The certification agency is TÜV Süd Management Service. Furthermore, external quality inspections (external monitoring) are carried out by an external, recognised state materials testing institute and further quality audits for export approvals. Declared unit: The declared unit is 1 m produced Rhenofol CV and Rhenofol CG roofing membrane with a sealing layer of 1.5 mm.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 22.13
  • 0.01299
  • 0.02724
  • 0
  • 0.006496
  • 1.792
  • 0
  • -12.16
Input
  • 1.474
  • 0
  • -0.0261
  • 0
  • 0
  • -1.448
  • 0
  • 0
Input
  • 23.61
  • 0.01299
  • 0.00114
  • 0
  • 0.006496
  • 0.3446
  • 0
  • -12.16
Input
  • 71.91
  • 0.1942
  • 0.3236
  • 0
  • 0.09708
  • 41.82
  • 0
  • -31.73
Input
  • 40.97
  • 0
  • -0.3197
  • 0
  • 0
  • -40.65
  • 0
  • 0
Input
  • 112.9
  • 0.1942
  • 0.003942
  • 0
  • 0.09708
  • 1.167
  • 0
  • -31.73
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.0353
  • 0.00001156
  • 0.00005285
  • 0
  • 0.00000578
  • 0.01071
  • 0
  • -0.004324
Output
  • 0.000001053
  • 3.272E-13
  • 5.615E-14
  • 0
  • 1.636E-13
  • 1.854E-11
  • 0
  • -1.902E-9
Output
  • 0.2897
  • 0.00002905
  • 0.0001315
  • 0
  • 0.00001453
  • 0.09511
  • 0
  • -0.01709
Output
  • 0.001254
  • 2.555E-7
  • 1.18E-7
  • 0
  • 1.278E-7
  • 0.00003549
  • 0
  • -0.001258
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.04226
  • 0
  • 0
  • 7.475
  • 0
  • 0
Output
  • 0
  • 0
  • 0.09741
  • 0
  • 0
  • 17.15
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 4.869
  • 0.01437
  • 0.02413
  • 0
  • 0.007184
  • 4.618
  • 0
  • -2.057
  • -0.1097
  • 0.0000518
  • 0.002274
  • 0
  • 0.0000259
  • 0.1571
  • 0
  • -0.01853
  • 4.976
  • 0.01423
  • 0.02186
  • 0
  • 0.007115
  • 4.461
  • 0
  • -2.039
  • 0.002941
  • 0.00008525
  • 4.481E-8
  • 0
  • 0.00004263
  • 0.00002558
  • 0
  • -0.000187
  • 4.626E-11
  • 3.516E-15
  • 2.335E-15
  • 0
  • 1.758E-15
  • 7.031E-13
  • 0
  • -2.5E-11
  • 0.01296
  • 0.00001009
  • 0.000002011
  • 0
  • 0.000005047
  • 0.001055
  • 0
  • -0.001953
  • 0.01315
  • 0.00001201
  • 0.00000398
  • 0
  • 0.000006007
  • 0.001308
  • 0
  • -0.002055
  • 0.02817
  • 0.00004386
  • 0.0000186
  • 0
  • 0.00002193
  • 0.006252
  • 0
  • -0.00808
  • 0.00005986
  • 3.359E-8
  • 5.803E-10
  • 0
  • 1.68E-8
  • 1.959E-7
  • 0
  • -0.000005538
  • 0.002641
  • 0.000003441
  • 7.521E-7
  • 0
  • 0.00000172
  • 0.0004046
  • 0
  • -0.0007605
  • 0.7186
  • 0.00007483
  • 0.002253
  • 0
  • 0.00003741
  • 0.4549
  • 0
  • -0.02696
  • 0.008403
  • 1.027E-9
  • 1.746E-11
  • 0
  • 5.134E-10
  • 5.282E-9
  • 0
  • -1.78E-7
  • 112.8
  • 0.1938
  • 0.00394
  • 0
  • 0.09688
  • 1.167
  • 0
  • -31.72

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 1.766E-9
  • 2.821E-12
  • 1.639E-13
  • 0
  • 1.41E-12
  • 4.721E-11
  • 0
  • -3.865E-10
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 1.258E-7
  • 1.411E-10
  • 4.984E-12
  • 0
  • 7.054E-11
  • 2.826E-9
  • 0
  • -1.204E-8
Incidence of disease due to PM emissions (PM) 2
  • 5.283E-7
  • 8.846E-11
  • 2.436E-11
  • 0
  • 4.423E-11
  • 7.145E-9
  • 0
  • -1.496E-8
Human exposure efficiency relative to U235 (IR) 1
  • 0.1424
  • 0.00002737
  • 0.00001247
  • 0
  • 0.00001369
  • 0.00375
  • 0
  • -0.133
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 47.07
  • 0.14
  • 0.001517
  • 0
  • 0.07002
  • 0.4217
  • 0
  • -5.419
Soil quality index (SQP) 2
  • 37.71
  • 0.06897
  • 0.001227
  • 0
  • 0.03449
  • 0.3512
  • 0
  • -8.444