Close Collapse all sections
Process Data set: MFT-FOX VTR (en) en de

Key Data Set Information
Location RER
Reference year 2024
Name
MFT-FOX VTR
Use advice for data set Scope: This document relates to the MFT-FOX VTR 300 L 6,5 as a representative product for the MFT-FOX VTR portfolio. FOX VTR products cover the same applications and are equal in material constitution and have therefore been summarized in this EPD. System boundary: Type of EPD: Cradle to factory gate with modules C1-C4 and D. The following information modules are defined as systemboundaries in this study: Production stage (A1- A3): - A1, raw material extraction, - A2, transport to the manufacturer, - A3, production. End of life (C1- C4): - C1, dismantling/demolition, - C2, transport, - C3, waste treatment , - C4, disposal. Reuse, recovery and recycling potential (D) In order to accurately record the indicators and environmental impacts of the declared unit, a total of 8 information modules are considered. The information modules A1 to A3 describe the provision of materials, transport to the production site and the production processes of the product itself. The primary products are sourced from the European Union. They are transported by lorry and container ship. The following flow charts illustrate the underlying production process. Figure Information modules A 1 to A3 of the product. Figure Information modules A 1 to A3 of the packaging. In the information modules C1 to C4, the deconstruction or demolition from the building, the transport to waste disposal,the waste treatment and disposal of the product are recorded.Furthermore, reuse, recovery and recycling potentials arereported in information module D.
Technical purpose of product or process The application of the MFT FOX VTR product group is explained on the basis of the Bracket MFT-FOX VTR 300 L 6,5. The bracket can be used for the fastening of substructures for ventilated facades to concrete, masonry, SFS, and wood. The mounting of facade substructures on the main structure is supported by an auxiliary console that temporarily holds the rails in position during fastening. The installation of vertical support rails is also possible. These fastening techniques are suitable for all facade claddings.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 4.2.04 Metalle / Edelstahl / Befestigungsmittel
  • IBUCategories: 02 Building products / Metallic products and ancillaries / Building metals
General comment on data set MFT-FOX VTR is designed as a steel substructure bracket. The brackets are suitable for all faade cladding. The products are used for fastening ventilated faade substructure to concrete, masonry, steel frame structure and wood. They enable mounting faade substructures on the primary structure as a helping hand bracket and can be used to install vertical support rails.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • gross density: 8.0 kg/m^3
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system MFT-FOX VTR is designed as a steel substructure console. The brackets are suitable for all façade claddings. The products are used for fixing ventilated façade substructures to concrete, masonry, steel frame constructions and wood. They enable assembly of façade substructures to the primary structure as the primary structure and can be used for mounting vertical supports. Rails. Technical data: Technical documentation according to EN 1090-1. Declared unit: The declared product here is a screw from HILTI AG with the designation MFT-FOX VTR 300 L as a representative product from the MFT-VTR bracket portfolio. The declared unit refers to 1 kg of steel substructure bracket. The packaging, based on 1 kg of steel substructure bracket, is also included in the calculation at 0.03 kg.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 10.98
  • 0.176
  • 0.00794
  • 0.00468
  • 0
  • -8.35
Input
  • 0.45
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 11.43
  • 0.176
  • 0.00794
  • 0.00468
  • 0
  • -8.35
Input
  • 51.53
  • 1.29
  • 0.112
  • 0.0505
  • 0
  • -38.1
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 51.53
  • 1.29
  • 0.112
  • 0.0505
  • 0
  • -38.1
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.02675
  • 0.000295
  • 0.00000875
  • 0.0000144
  • 0
  • -0.0207
Output
  • 8.102E-10
  • 7.46E-11
  • 4.16E-13
  • -1.31E-13
  • 0
  • -6.03E-10
Output
  • 0.3807
  • 0.000284
  • 0.0000162
  • 0.0000133
  • 0
  • -0.298
Output
  • 0.001887
  • 0.000201
  • 1.45E-7
  • 6.77E-7
  • 0
  • -0.00136
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0

IndicatorUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 3.827
  • 0.05863
  • 0.008456
  • 0.002579
  • 0
  • -2.842
  • 0.0000332
  • 0.0000292
  • 0
  • 0
  • 0
  • 0
  • 3.824
  • 0.0586
  • 0.00838
  • 0.00256
  • 0
  • -2.84
  • 0.003623
  • 0.00000536
  • 0.0000764
  • 0.0000192
  • 0
  • -0.0018
  • 1.295E-11
  • 5.76E-13
  • 7.22E-16
  • 4.28E-15
  • 0
  • -9.91E-12
  • 0.008729
  • 0.0000695
  • 0.0000298
  • 0.0000166
  • 0
  • -0.00632
  • 0.02631
  • 0.0000892
  • 0.0000329
  • 0.0000134
  • 0
  • -0.02
  • 0.03174
  • 0.000266
  • 0.000173
  • 0.0000677
  • 0
  • -0.0221
  • 0.000004956
  • 5.79E-8
  • 3.01E-8
  • 8.71E-9
  • 0
  • -0.00000343
  • 0.00285
  • 0.0000252
  • 0.0000155
  • 0.00000613
  • 0
  • -0.00199
  • 0.8377
  • 0.00492
  • 0.0000951
  • 0.000498
  • 0
  • -0.654
  • 0.000114
  • 2.84E-9
  • 5.32E-10
  • 2.74E-9
  • 0
  • -0.0000894
  • 51.52
  • 1.29
  • 0.112
  • 0.0504
  • 0
  • -38.1

IndicatorUnit Production
A1-A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Incidence of disease due to PM emissions (PM) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Human exposure efficiency relative to U235 (IR) 1
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for ecosystems (ETP-fw) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Soil quality index (SQP) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND