Close Collapse all sections
Process Data set: Sliding door gear (en) en

A superceding data set exists.

View superceding data set

Key Data Set Information
Location EU-27
Reference year 2016
Name
Sliding door gear
Use advice for data set Scope: This ARGE EPD covers hardware systems for sliding doors, sliding corner doors, sliding folding doors, sliding gates used for buildings, mechanisms used to support doors of varying materials and allow their opening and closing via a sliding action. It does not include sliding folding windows or door height windows. The reference product used to calculate the impact this product group has on the environment is an item of sliding door gear composed primarily of aluminium and has been selected for the LCA (Life Cycle Assessment) because it is the product with the highest impact for 1 kg of product. A validity scope analysis has also been carried out to determine the limiting factors for sliding door gear covered by this EPD. In a preliminary study (simplified LCA), it has been confirmed that this EPD represents the worst case condition and it can therefore be used to cover all sliding door gear manufactured in Europe by ARGE member companies. System boundary: The type of the EPD covers “cradle to grave” requirements. The analysis of the product life cycle includes the production and transport of the raw materials, manufacture of the product and the packaging materials, which are declared in modules A1-A3. Losses during production are considered as waste and are sent for recycling. No recycling processes are taken into account except transport and electricity consumption for grinding the metals. When recycled metals are used as raw material, only their transformation process is taken into account and not the extraction of the raw material. A4 module represents the transport of the finished product to the installation site. There is no waste associated with the installation of the product. The A5 module therefore represents only the disposal of the product packaging. For the RSL considered for this study, there are no inputs or outputs for the stages B1-B7. The End-of-Life (EoL) stages are also considered. The transportation to the EoL disposal site is taken into account in module C2. Module C4 covers the disposal of the sliding door gear. Module C3 covers the recycling of the individual elements according to European averages, with the remaining waste divided between incineration and landfill. The same assumption as for waste to recycling in A3 is used here. For end of life modules (C1 to C4) the system boundaries from the XP P01-064/CN standard have been followed, see annex H.2 and H.6 of this document for figures and further details. In practice, the end of life has been modelled as follows: - When a material is sent for recycling generic transport and electric consumption of a shredder is taken into account (corresponding to the process “Grinding, metals”). Only then, is the material considered to have attained the “end of waste” state. - Each type of waste is modelled as a transport to the treatment site with a distance of 30 km (source: FD P01-015). Parts sent for recycling include an electricity consumption (grinding) and a flow (“Materials for recycling, unspecified”). Four scenarios for the end of life of the products have been declared for this EPD: 1. 100% of the product going in landfill 2. 100% of the product going in incineration 3. 100% of the product going in recycling 4. Mixed scenario consisting of the previous three scenarios, values depending of the amount of waste going to recycling. Module D has not been declared.
Technical purpose of product or process These products are designed to be integrated into door assemblies of varying materials and applications. . Their purpose is to ensure the fastening of the door, window or shutter, and to open and close it safely. They may be used for either interior or exterior doors.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: / /
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Building Hardware products
General comment on data set This EPD refers to sliding door gear intended to be used in buildings. The sample group used to calculate the LCA data for this Association EPD includes all functional gear necessary to move safely a sliding door
Scenarios
  • Scenario: S0 (Default) - Scenario 0
  • Scenario: S1 - Incineration
  • Scenario: S3 - Recycling
  • Scenario: S2 - Landfilling
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Time representativeness
Data set valid until 2021
Technological representativeness
Technology description including background system The production of a sliding door gear normally follows a 3 step procedure: 1. Preparation of semi-finished components, this step might include a surface treatment on factory site or by external manufacturers. 2. Preassembly of assembly modules (onsite factory) 3. Final assembly (onsite factory) Technical data: Ideally, products should comply with a suitable technical specification. /EN 1527 is an example of such a specification and some products will comply with this. The relevant grading structure is shown in the following table Declared unit: The declared unit for all products covered by ARGE EPD is 1 kg (of product). Since individual products will rarely weigh exactly 1 kg it is necessary to establish the exact weight of the product then use this as a correction factor to determine the true values for 1 kg of product in the tables (Section 5). A total of six typical products (based on sales figures) have been evaluated, and the worst case results are used in the tables.
Flow diagram(s) or picture(s)
  • Sliding door gear acc. to the classification in EN 1527 and EN 13126-15 Image
  • Correction factor Image

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
S0 (Default)
Transport
C2
S1
Transport
C2
S2
Transport
C2
S3
Waste processing
C3
S0 (Default)
Waste processing
C3
S1
Waste processing
C3
S2
Waste processing
C3
S3
Disposal
C4
S0 (Default)
Disposal
C4
S1
Disposal
C4
S2
Disposal
C4
S3
Input
  • 45.8
  • 0.112
  • 0.00206
  • 0
  • 0.000961
  • 0.000961
  • 0.000961
  • 0.000961
  • 0.00961
  • 0
  • 0
  • 0.0172
  • 0.000415
  • 0.0114
  • 0.0211
  • 0
Input
  • 2.21
  • 0
  • -1.4
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 48
  • 0.112
  • -1.4
  • 0
  • 0.000961
  • 0.000961
  • 0.000961
  • 0.000961
  • 0.00961
  • 0
  • 0
  • 0.0172
  • 0.000415
  • 0.0114
  • 0.0211
  • 0
Input
  • 1.2E+2
  • 9.13
  • 0.0395
  • 0
  • 0.0782
  • 0.0782
  • 0.0782
  • 0.0782
  • 0.109
  • 0
  • 0
  • 0.195
  • 0.0092
  • 0.386
  • 0.353
  • 0
Input
  • 0.994
  • 0
  • -0.0697
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 121
  • 9.13
  • -0.0302
  • 0
  • 0.0782
  • 0.0782
  • 0.0782
  • 0.0782
  • 0.109
  • 0
  • 0
  • 0.195
  • 0.0092
  • 0.386
  • 0.353
  • 0
Input
  • 0.455
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.181
  • 0.00172
  • 0.0000277
  • 0
  • 0.0000148
  • 0.0000148
  • 0.0000148
  • 0.0000148
  • 0.0000366
  • 0
  • 0
  • 0.0000654
  • 0.000018
  • 0.00117
  • 0.000342
  • 0
Output
  • 2.53
  • 0.00564
  • 0.000313
  • 0
  • 0.0000483
  • 0.0000483
  • 0.0000483
  • 0.0000483
  • 0.000343
  • 0
  • 0
  • 0.000614
  • 0.00307
  • 0.266
  • 0.00124
  • 0
Output
  • 3.14
  • 0.468
  • 0.0254
  • 0
  • 0.00401
  • 0.00401
  • 0.00401
  • 0.00401
  • 0.00155
  • 0
  • 0
  • 0.00277
  • 0.0137
  • 0.0145
  • 1
  • 0
Output
  • 0.000498
  • 0.0000613
  • 2.23E-7
  • 0
  • 5.25E-7
  • 5.25E-7
  • 5.25E-7
  • 5.25E-7
  • 5.89E-7
  • 0
  • 0
  • 0.00000105
  • 5.12E-8
  • 0.00000135
  • 0.00000265
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.321
  • 0
  • 0.0994
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.559
  • 0
  • 0
  • 1
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.00657
  • 0
  • 0.0328
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.016
  • 1.39
  • 0
  • 0
Output
  • 0.0133
  • 0
  • 0.0682
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.0327
  • 2.85
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
S0 (Default)
Transport
C2
S1
Transport
C2
S2
Transport
C2
S3
Waste processing
C3
S0 (Default)
Waste processing
C3
S1
Waste processing
C3
S2
Waste processing
C3
S3
Disposal
C4
S0 (Default)
Disposal
C4
S1
Disposal
C4
S2
Disposal
C4
S3
  • 9.01
  • 0.589
  • 0.0136
  • 0
  • 0.00505
  • 0.00505
  • 0.00505
  • 0.00505
  • 0.00485
  • 0
  • 0
  • 0.00866
  • 0.0127
  • 0.523
  • 0.497
  • 0
  • 7.27E-7
  • 1.08E-7
  • 3.6E-10
  • 0
  • 9.26E-10
  • 9.26E-10
  • 9.26E-10
  • 9.26E-10
  • 5.2E-10
  • 0
  • 0
  • 9.3E-10
  • 9.25E-11
  • 4.02E-9
  • 3.43E-9
  • 0
  • 0.0063
  • 0.000268
  • 0.00000322
  • 0
  • 0.0000023
  • 0.0000023
  • 0.0000023
  • 0.0000023
  • 0.00000111
  • 0
  • 0
  • 0.00000198
  • 0.00000208
  • 0.000016
  • 0.000141
  • 0
  • 0.075
  • 0.00239
  • 0.0000141
  • 0
  • 0.0000205
  • 0.0000205
  • 0.0000205
  • 0.0000205
  • 0.0000201
  • 0
  • 0
  • 0.000036
  • 0.00000465
  • 0.000258
  • 0.000124
  • 0
  • 0.00501
  • 0.000406
  • 0.00000629
  • 0
  • 0.00000348
  • 0.00000348
  • 0.00000348
  • 0.00000348
  • 0.00000226
  • 0
  • 0
  • 0.00000404
  • 0.00000887
  • 0.0000752
  • 0.000594
  • 0
  • 0.0000224
  • 0.00000195
  • 4.1E-9
  • 0
  • 1.67E-8
  • 1.67E-8
  • 1.67E-8
  • 1.67E-8
  • 1.97E-9
  • 0
  • 0
  • 3.53E-9
  • 8.73E-10
  • 4.69E-8
  • 2.47E-8
  • 0
  • 102
  • 8.97
  • 0.0331
  • 0
  • 0.0769
  • 0.0769
  • 0.0769
  • 0.0769
  • 0.0744
  • 0
  • 0
  • 0.133
  • 0.00806
  • 0.373
  • 0.28
  • 0