Close Collapse all sections
Process Data set: VELUX roof balcony and terrace window (en) en de

A superceding data set exists.

View superceding data set

Key Data Set Information
Location RER
Reference year 2024
Name
VELUX roof balcony and terrace window
Use advice for data set Scope: The EPD is a representative EPD covering VELUX terrace and balcony windows as specified in more detail in the product description. The products are manufactured by the VELUX Group at production sites in different locations in Europe for sale throughout Europe. The windows final assembly take place in Denmark. System boundary: The type of the EPD is "cradle to gate - with options" including the modules C1-C4 and D. The following life cycle phases were considered: Product stage: A1 - Raw material supply: extraction and processing, production of the pre-products (e.g. laminated glass, sawn pine wood, metal/plastic components, sealants etc.) and sales packaging components (e.g., cardboard). A2 - Transport: Transport of pre-products and packaging components to the processing or assembly sites, as well as internal transportation of components between sites. A3 - Manufacturing: The wooden frames/sashes and glazing units are produced internally at VELUX production sites. Subsequently, the final production and assembly of the windows takes place, which involves activities such as shortening of profiles, drilling of holes, clamping and glueing, mounting of gaskets, brackets, panes etc. End of life stage: C1 - De-construction/demolition: deconstruction of the window with the use of an electric screwdriver and manual work. C2 - Transport: transport of window materials to Material Recovery Facilities (MRF) and then to incineration, landfill or recycling facilities. C3 - Waste processing: sorting of waste, recycling (metal and glass waste), incineration (plastic and wood waste) and landfill (metal, glass, wood and plastic waste). C4 - Disposal: disposal of all materials Benefits and loads beyond the system boundaries: D - Reuse, recovery and recycling potential: benefits from plastic and wood waste incineration processes and material recycling of metal and glass. For the environmental impact, the use of green electricity was calculated taking into account the residual electricity mix for the remaining electricity. The proportion of the electricity demand covered by green electricity in the total electricity demand is 79.23 %.
Technical purpose of product or process VELUX roof balcony and terrace are used in renovation and new build. Either installed as a single window or in a combination of multiple windows.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.8.01 Komponenten von Fenstern und Vorhangfassaden / Fenster / Holzfenster
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Windows and doors
General comment on data set The VELUX roof balcony and terrace are skylight window products for sale in the European market. The product family covers a range of product varieties as specified in the table below. The terrace window consists of a combination between the GEL variant (top) and either VEA, VEB or VEC variants (bottom). The terrace window is available in one size (2.45 m x 0.78 m), while the different variants in the window are not available as individual windows. The balcony window (GDL) consists of an upper and a lower section. All windows have a wooden frame/sash. Some windows can be opened (venting), while others cannot be opened (fixed). In addition, the windows consist of 4 different hinge-functionalities (pivot-hung, top-hung, side-hung, bottom-hung). The handles and handlebars are made of aluminium, while the hinges are made of steel (galvanised, stainless). The windows are opened and closed manually. The calculations are based on the representative terrace window type named GEL+VEA. In the LCA, the GEL+VEA was assessed to be a conservative choice for a representative window type. The glass panes are with triple glazing (3-layer glazing unit) and different glass configurations are covered by the EPD. The glass thickness ranges from 10 to 13 mm. The glass panes have cavities filled with Krypton gas. The EPD is based on a weighted average of the included glazing unit configurations. The included glazing unit configurations are: 65 G and 66. Only the window modules are included, which means that any applied installation products, accessories, etc. are not part of the EPD. These are available as separate EPDs, that can be used in combination with this EPD. 1 3-layer glazing options: 65 G, 66
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • layer thickness: 0.0393 m
    • grammage: 49.58 kg/m^2
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system The main components of the VELUX roof balcony and terrace are the glazing unit (made of mainly laminated and tempered glass), wooden frames/sashes (made of wood), hinges (made of steel) and handles/handlebars (made of aluminium). The packaging of the products consists of mostly wood and cardboard along paper insert, EPS, PE LD and galvanised steel. The wooden components (sashes, frames) are produced internally in VELUX facilities, located in Hungary, Poland, and Denmark. VELUX receives sawn pine wood (dried) and process it (sawing, cutting etc.) into lamellas of different quality. The lamellas are then glued together (lamination) and processed into profiles (cutting them into the correct size, cladding, drilling etc.). For the glazing units, VELUX receives the glazing units components from suppliers and produces the final glazing units in a site located in Denmark. After their production, the glazing units join the window assembly process. Finally, the frames/sashes, glazing unit and the rest of the components (delivered by suppliers) are transported to VELUX assembly sites in Denmark, where they are assembled into the final window product. Technical data: The Declaration of Performance including relevant technical specifications and test methods/test standards can be downloaded from the website: www.velux.com/ce The performance values are specific for each standard wooden roof window variant covered by the EPD. The declared values in the table relate to the reference product including the variants GEL and VEA with triple-glazed configuration 65G. The technical data between the variants GEL and VEA differ only for "impact resistance". For other covered product variants, specific values can be selected at the bottom of the above-mentioned download page. Declared unit: Multiple product dimensions are represented by this EPD as specified in the product description. The declared unit is 1 m2 roof balcony and terrace calculated based on the standard window size (1.23 m x 1.48 m based on EN 17213.2020) with triple glazed window panes (65 G, 66). Since the frame/sash construction is alike across all variants in the product group, the parts that set the variants apart are primarily the window-operation components, such as hinges, handles and ventilation flaps. These components are to a high degree metal-based, and the worst-case product can thus be identified by the weight of products with similar size and glazing unit. The heavier the product, the larger the content of metal. The variant GEL combined with VEA (GEL+VEA) present the largest weight per m2 across the product group of terrace windows and the balcony window GDL. Therefore, the GEL combined with VEA variant can be considered more representative as worst-case scenario for the whole windows product group.

Indicators of life cycle

IndicatorDirectionUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 389.7
  • 0.3609
  • 1179
  • 0.004208
  • 2.224
  • 197.8
  • 0.4923
  • -130.9
Input
  • 445.2
  • 0
  • 120.8
  • 0
  • 0
  • -195.9
  • 0
  • 0
Input
  • 834.9
  • 0.3609
  • 1.3E+3
  • 0.004208
  • 2.224
  • 1.832
  • 0.4923
  • -130.9
Input
  • 1824
  • 6.313
  • 615.1
  • 0.04085
  • 38.79
  • 109
  • 4.035
  • -563.8
Input
  • 136
  • 0
  • 1.551
  • 0
  • 0
  • -98.59
  • 0
  • 0
Input
  • 1.96E+3
  • 6.313
  • 616.6
  • 0.04085
  • 38.79
  • 10.4
  • 4.035
  • -563.8
Input
  • 4.621
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.7966
  • 0.0004133
  • 0.1352
  • 0.000009199
  • 0.002547
  • 0.0709
  • 0.0009344
  • -0.3039
Output
  • 0.002923
  • 3.317E-10
  • 0.00003875
  • 4.912E-12
  • 2.044E-9
  • 1.73E-9
  • 4.886E-10
  • -5.979E-8
Output
  • 12.21
  • 0.0009893
  • 0.6791
  • 0.000007676
  • 0.006086
  • 1.563
  • 16.57
  • -5.509
Output
  • 0.05671
  • 0.00001144
  • 0.03008
  • 0.00000661
  • 0.00007037
  • 0.0004217
  • 0.0000432
  • -0.026
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.01675
  • 0
  • 21.68
  • 0
  • 0
  • 16.76
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 15.28
  • 0
  • 0
Output
  • 0.03326
  • 0
  • 0
  • 0
  • 0
  • 45.11
  • 0
  • 0
Output
  • 0.04854
  • 0
  • 0
  • 0
  • 0
  • 82.08
  • 0
  • 0

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 96.42
  • 0.4761
  • 53.3
  • 0.001973
  • 2.925
  • 27.27
  • 4.05
  • -44.87
  • -45.15
  • -0.0005586
  • 12.82
  • 0.000001105
  • 0.03092
  • 20.33
  • 3.75
  • -0.0815
  • 141.3
  • 0.4728
  • 40.44
  • 0.001971
  • 2.87
  • 6.936
  • 0.3014
  • -44.77
  • 0.1035
  • 0.003848
  • 0.04694
  • 3.376E-7
  • 0.02372
  • 0.001462
  • 0.000759
  • -0.01546
  • 0.000001253
  • 9.311E-17
  • 1.129E-7
  • 2.218E-17
  • 5.729E-16
  • -6.475E-9
  • 1.077E-15
  • -9.689E-14
  • 0.3328
  • 0.0004777
  • 0.08982
  • 0.000002391
  • 0.01583
  • 0.007777
  • 0.002074
  • -0.08805
  • 0.584
  • 0.000543
  • 0.09862
  • 0.000003184
  • 0.01746
  • 0.007059
  • 0.002038
  • -0.1654
  • 1.313
  • 0.002072
  • 0.3557
  • 0.000009027
  • 0.09447
  • 0.0364
  • 0.006091
  • -0.3483
  • 0.005491
  • 0.000001399
  • 0.0005981
  • 7.922E-10
  • 0.000008621
  • -0.00001408
  • 0.00000431
  • -0.00002528
  • 0.1178
  • 0.0001756
  • 0.03495
  • 8.426E-7
  • 0.008536
  • 0.002878
  • 0.0005749
  • -0.03162
  • 11.72
  • 0.004371
  • 2.131
  • 0.0001579
  • 0.02693
  • 3
  • 0.03105
  • -3.396
  • 0.002007
  • 4.177E-8
  • 0.00004273
  • 2.44E-10
  • 2.572E-7
  • 5.822E-8
  • 2.673E-8
  • -0.00001113
  • 1958
  • 6.29
  • 616.2
  • 0.04084
  • 38.65
  • 10.39
  • 4.033
  • -562.4

IndicatorUnit Raw material supply
A1
Transport
A2
Manufacturing
A3
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 0.000001004
  • 9.436E-11
  • 2.836E-8
  • 2.094E-13
  • 5.801E-10
  • 2.639E-10
  • 3.05E-10
  • -3.213E-8
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 0.000002235
  • 4.895E-9
  • 5.44E-7
  • 1.155E-11
  • 3.555E-8
  • 1.717E-8
  • 3.432E-8
  • -3.845E-7
Incidence of disease due to PM emissions (PM) 2
  • 0.00001156
  • 4.352E-9
  • 9.711E-7
  • 2.902E-11
  • 7.556E-8
  • 6.147E-8
  • 2.444E-8
  • -0.000001646
Human exposure efficiency relative to U235 (IR) 1
  • 11.55
  • 0.001673
  • 3.031
  • 0.0009662
  • 0.01029
  • 0.05431
  • 0.004904
  • -4.921
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 2002
  • 4.667
  • 168.2
  • 0.01255
  • 28.68
  • 5.807
  • 2.85
  • -221.1
Soil quality index (SQP) 2
  • 8245
  • 2.155
  • 1385
  • 0.003385
  • 13.28
  • 1.78
  • 0.7048
  • -32.35