Close Collapse all sections
Process Data set: Stainless steel lever and window handle CORE/PREMIUM (en) en de

Key Data Set Information
Location GLO
Reference year 2024
Name
Stainless steel lever and window handle CORE/PREMIUM
Use advice for data set Scope: This Environmental Product Declaration refers to a specific stainless steel lever handle manufactured by OGRO. The EPD isalso representative for stainless steel window handles. The production site is located in Velbert (Germany). Data represents the year 2023. System boundary: The type of EPD is according to EN 15804: "cradle to gate with options, modules C1–C4, and module D".The following modules are declared: A1-A3, C1-C4, D and additional modules: A4 + A5 Production - Module A1-A3 The product stage includes:— A1, raw material extraction, processing and mechanical treatments, processing of secondary material input (e.g. recycling processes),— A2, transport to the manufacturer,— A3, manufacturing and assembly including provision of all materials, products and energy, as well as waste processing up to the end-of waste state. Construction stage - Modules A4-A5 The construction process stage includes:— A4, transport to the building site;— A5, installation into the building; including provision of all materials, products and energy, as well as waste processing up to the end-of waste state or disposal of final residues during the construction process stage. End-of-life stage– Modules C1-C4 and D The end-of-life stage includes:— C1, de-construction, demolition:— C2, transport to waste processing;— C3, waste processing for reuse, recovery and/or recycling;— C4, disposal; including provision and all transport, provision of all materials, products and related energy and water use. Module D (Benefits and loads beyond the system boundary) includes:— D, recycling potentials, expressed as net impacts and benefits.
Technical purpose of product or process The lever an window handles are suitable for practically all applications: Lever handles: For use on doors which are subject to frequent force, e.g. football stadiums, military barracks, schools, public toilets For extremely high-traffic areas and intensive use in buildings Use in public buildings, e.g. hospitals or administrative buildings Manifold barrier-free applications Use on glass doors Use on mechanically high-strength apartment entrance doors with requirements incl. in accordance with DIN 18257 Use on panic, escape, rescue and fire safety doors Use on doors with electronic access control Window handles: For use on wooden, plastic or aluminium profiles For high-traffic areas and intensive use in buildings Use in public buildings, e.g. hospitals or administrative buildings Suitable for all standard window handle gears with variable pin adjustment Simple operation with forces according to EN standards
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.4.01 Komponenten von Fenstern und Vorhangfassaden / Beschläge / Stahlbeschläge
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Building Hardware products
General comment on data set OGRO Beschlagtechnik GmbH manufactures door and window fittings made of stainless steel or aluminium for the premium real estate market. This EPD declares OGRO Premium and CORE lever and window handles made of stainless steel.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 0.619 kg
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system OGRO Beschlagtechnik GmbH manufactures door and window fittings made of stainless steel or aluminium fort he premium real estate market. This Declaration concerns OGRO Premium and CORE lever and window handles. Technical data: The stainless steel lever and window handles comply with following standards: DIN 17440: Steel and steel alloys EN 179: Locks and fittings EN 1125: Locks and fittings EN 1634: Fire resistance and smoke control tests for door and shutter assemblies EN 1906: Requirements and test methods for lever handles and knob furniture EN 13126-3: Building hardware - Hardware for windows and door height windows DIN 18082, Part 1: Fire protection barriers, steel doors T 30-1 DIN 18095, Parts 1 + 2: Smoke control doors DIN 18255: Building hardware DIN 18257: Security plates DIN 18273: Lever handle units for fire doors and smoke control doors DIN 4102, Parts 5 + 18: Fire behaviour of building materials and building components DIN 18040: Construction of accessible buildings Declared unit: The declared unit is 1 piece of the product: Stainless steel lever and window handle:

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 10.11
  • 0.000268
  • 1.184
  • 0
  • 0.0001157
  • 0.009
  • 0
  • -4.8
Input
  • 1.176
  • 0
  • -1.176
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 11.28
  • 0.000268
  • 0.008
  • 0
  • 0.0001157
  • 0.009
  • 0
  • -4.8
Input
  • 38.43
  • 0.085
  • 0.044
  • 0
  • 0.037
  • 0.499
  • 0
  • -24.08
Input
  • 0.462
  • 0
  • 0
  • 0
  • 0
  • -0.462
  • 0
  • 0
Input
  • 38.89
  • 0.085
  • 0.044
  • 0
  • 0.037
  • 0.037
  • 0
  • -24.08
Input
  • 0.306
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.039
  • 4.808E-7
  • 0.0004056
  • 0
  • 2.075E-7
  • 0.0001928
  • 0
  • -0.029
Output
  • 2.131E-7
  • 8.252E-12
  • 6.465E-11
  • 0
  • 3.562E-12
  • 1.392E-10
  • 0
  • -1.399E-7
Output
  • 0.245
  • 0.000008699
  • 0.004
  • 0
  • 0.000003755
  • 0.008
  • 0
  • -0.163
Output
  • 0.0006647
  • 9.132E-8
  • 0.000002306
  • 0
  • 3.942E-8
  • 0.000001356
  • 0
  • -0.0001993
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0.588
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.21
  • 0
  • 0
  • 0.146
  • 0
  • 0
Output
  • 0
  • 0
  • 0.381
  • 0
  • 0
  • 0.335
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 2.901
  • 0.006
  • 0.139
  • 0
  • 0.003
  • 0.079
  • 0
  • -1.974
  • -0.1608
  • 0.0002771
  • 0.135
  • 0
  • 0.0001196
  • 0.000001836
  • 0
  • 0.009
  • 3.056
  • 0.006
  • 0.003
  • 0
  • 0.003
  • 0.079
  • 0
  • -1.979
  • 0.005313
  • 1.427E-7
  • 0.000002286
  • 0
  • 6.158E-8
  • 0.000004454
  • 0
  • -0.004
  • 1.098E-12
  • 6.328E-19
  • 2.504E-17
  • 0
  • 2.731E-19
  • 3.974E-17
  • 0
  • -4.273E-15
  • 0.006718
  • 0.000005397
  • 0.00003724
  • 0
  • 0.00000233
  • 0.000008753
  • 0
  • -0.004
  • 0.01485
  • 0.000005999
  • 0.00003891
  • 0
  • 0.000002589
  • 0.00001403
  • 0
  • -0.008
  • 0.023
  • 0.00002122
  • 0.0001752
  • 0
  • 0.00000916
  • 0.00006389
  • 0
  • -0.014
  • 0.000007026
  • 1.283E-9
  • 4.898E-9
  • 0
  • 5.537E-10
  • 6.338E-9
  • 0
  • -0.000001724
  • 0.002256
  • 0.000001909
  • 0.00001405
  • 0
  • 8.24E-7
  • 0.000003163
  • 0
  • -0.001
  • 1.024
  • 0.00001174
  • 0.017
  • 0
  • 0.00000507
  • 0.008
  • 0
  • -0.752
  • 0.0001169
  • 1.798E-10
  • 3.955E-10
  • 0
  • 7.76E-11
  • 5.45E-10
  • 0
  • -0.00005694
  • 38.86
  • 0.085
  • 0.044
  • 0
  • 0.037
  • 0.037
  • 0
  • -24.05

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 5.716E-7
  • 1.133E-12
  • 1.101E-12
  • 0
  • 4.892E-13
  • 1.187E-12
  • 0
  • -3.72E-9
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 5.369E-8
  • 4.847E-11
  • 4.771E-11
  • 0
  • 2.092E-11
  • 1.202E-10
  • 0
  • -1.063E-8
Incidence of disease due to PM emissions (PM) 2
  • 2.556E-7
  • 3.154E-11
  • 2.155E-10
  • 0
  • 1.361E-11
  • 1.79E-10
  • 0
  • -1.666E-7
Human exposure efficiency relative to U235 (IR) 1
  • 0.06803
  • 0.00001305
  • 0.0003568
  • 0
  • 0.000005633
  • 0.0001221
  • 0
  • -0.026
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 17.31
  • 0.06
  • 0.021
  • 0
  • 0.026
  • 0.014
  • 0
  • -11.84
Soil quality index (SQP) 2
  • 24.96
  • 0.0002185
  • 0.012
  • 0
  • 0.0000943
  • 0.011
  • 0
  • -3.352