Close Collapse all sections
Process Data set: Mortise Lock Saflok Quantum Pixel (en) en de

Key Data Set Information
Location GLO
Reference year 2024
Name
Mortise Lock Saflok Quantum Pixel
Use advice for data set Scope: This Environmental Product Declaration refers to a specific mortise lock manufactured by dormakaba. The EPD is representative for the Saflok Quantum Pixel Series. The production site is located in Montreal (Canada). Data represents the year 2023. System boundary: The type of EPD is: cradle to gate with options, modules C1–C4, and module D (A1–A3 + C + D and additional modules: A4+ A5) Production - Module A1-A3 The product stage includes: — A1, raw material extraction, processing and mechanical treatments, processing of secondary material input (e.g. recycling processes), — A2, transport to the manufacturer, — A3, manufacturing and assembly including provision of all materials, products and energy, as well as waste processing up to the end-of-waste state. Construction stage - Modules A4-A5 The construction process stage includes: — A4, transport to the building site; — A5, installation into the building; including provision of all materials, products and energy, as well as waste processing up to the end-of-waste state or disposal of final residues during the construction process stage. Maintenance – Module B2 This module includes the production and the end of life of the batteries. The potential use of batteries is declared in module B2. End-of-life stage– Modules C1-C4 and D The end-of-life stage includes: — C1, de-construction, demolition: — C2, transport to waste processing; — C3, waste processing for reuse, recovery and/or recycling; — C4, disposal; including provision and all transport, provision of all materials, products and related energy and water use. Module D (Benefits and loads beyond the system boundary) includes: — D, recycling potentials, expressed as net impacts and benefits.
Technical purpose of product or process The mortise lock Saflok Quantum Pixel is ideal for new construction projects or in case that doors need to be replaced. The lock series is suitable for small to very large-scale hotels. The mortise locks are for interior doors only. One application is the access control for quest rooms.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 7.4.01 Komponenten von Fenstern und Vorhangfassaden / Beschläge / Stahlbeschläge
  • IBUCategories: 02 Building products / Doors, windows, shutters, and related products / Electronic and physical Access Control Systems
General comment on data set Saflok Quantum Pixel is the newest addition to dormakabas award-winning Quantum Series of RFID electronic locks. The Quantum Pixel provides an easy-to use, secure, and flexible solution that is both visually attractive and high-performing. With its electronics concealed within the door, the Quantum Pixels visible hardware is minimal resulting in a lock design that integrates seamlessly with any hotel decor. For the use and application of the product the representative national provisions apply. For the Saflok Quantum Pixel the standards which can be applied are the following: • ANSI A156.13 • ANSI A156.25 • UL 10C • ULC CAN S-104 • EN 14846 • EN 1634-1 • EN 1363-1
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • weight per piece: 3.5 kg
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system Saflok Quantum Pixel is the latest addition to dormakaba's award-winning Quantum series of electronic RFID locks. The Quantum Pixel offers an easy-to-use, secure and flexible solution that is both visually appealing and powerful. As the electronics are concealed within the door, the Quantum Pixel's visible hardware is minimal, resulting in a lock design that blends seamlessly into any hotel décor. Technical data: The Saflok Quantum Pixel has following technical properties:

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 117.2
  • 0.001
  • 6.393
  • 0.1972
  • 0
  • 0.0007027
  • 0.022
  • 0.004
  • -11.93
Input
  • 6.346
  • 0
  • -6.346
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 123.6
  • 0.001
  • 0.047
  • 0.1972
  • 0
  • 0.0007027
  • 0.022
  • 0.004
  • -11.93
Input
  • 637.7
  • 0.415
  • 0.838
  • 2.372
  • 0
  • 0.223
  • 6.818
  • 0.028
  • -63.34
Input
  • 7.319
  • 0
  • -0.585
  • 0
  • 0
  • 0
  • -6.734
  • 0
  • 0
Input
  • 645
  • 0.415
  • 0.253
  • 2.372
  • 0
  • 0.223
  • 0.084
  • 0.028
  • -63.34
Input
  • 1.95
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.3351
  • 0.000002347
  • 0.002
  • 0.0007226
  • 0
  • 0.00000126
  • 0.0004433
  • 0.000007103
  • -0.045
Output
  • 0.00002553
  • 4.028E-11
  • 4.1E-10
  • 1.145E-8
  • 0
  • 2.164E-11
  • 3.202E-10
  • 4.294E-10
  • -9.69E-7
Output
  • 1.862
  • 0.00004246
  • 0.027
  • 1.003
  • 0
  • 0.00002281
  • 0.019
  • 0.142
  • -0.18
Output
  • 0.01701
  • 4.458E-7
  • 0.00001304
  • 0.00004868
  • 0
  • 2.394E-7
  • 0.000003117
  • 3.207E-7
  • -0.002
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 2.78
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 1.198
  • 0
  • 0
  • 0
  • 1.183
  • 0
  • 0
Output
  • 0
  • 0
  • 2.204
  • 0
  • 0
  • 0
  • 2.745
  • 0
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
  • 53.97
  • 0.031
  • 0.784
  • 0.209
  • 0
  • 0.016
  • 0.181
  • 0.002
  • -4.663
  • -0.624
  • 0.001
  • 0.731
  • 0.0002883
  • 0
  • 0.0007264
  • 0.000004222
  • 0.000007335
  • 0.002
  • 54.54
  • 0.029
  • 0.053
  • 0.209
  • 0
  • 0.016
  • 0.181
  • 0.002
  • -4.659
  • 0.05702
  • 6.964E-7
  • 0.00001429
  • 0.00008675
  • 0
  • 3.74E-7
  • 0.00001024
  • 0.000006178
  • -0.006
  • 3.111E-9
  • 3.089E-18
  • 1.526E-16
  • 7.193E-16
  • 0
  • 1.659E-18
  • 9.138E-17
  • 7.959E-18
  • -1.967E-14
  • 0.191
  • 0.00002635
  • 0.0002048
  • 0.0007848
  • 0
  • 0.00001415
  • 0.00002013
  • 0.000012
  • -0.013
  • 0.377
  • 0.00002928
  • 0.0002162
  • 0.002113
  • 0
  • 0.00001573
  • 0.00003226
  • 0.0000154
  • -0.034
  • 0.705
  • 0.0001036
  • 0.0009733
  • 0.002323
  • 0
  • 0.00005563
  • 0.0001469
  • 0.00004355
  • -0.041
  • 0.0002903
  • 6.262E-9
  • 2.921E-8
  • 1.479E-7
  • 0
  • 3.363E-9
  • 1.458E-8
  • 3.687E-9
  • -0.000008605
  • 0.06587
  • 0.000009319
  • 0.00007721
  • 0.0002539
  • 0
  • 0.000005005
  • 0.000007274
  • 0.000003963
  • -0.004
  • 12.43
  • 0.00005733
  • 0.097
  • 0.02301
  • 0
  • 0.00003079
  • 0.019
  • 0.000225
  • -1.439
  • 0.02007
  • 8.775E-10
  • 2.374E-9
  • 0.000009052
  • 0
  • 4.713E-10
  • 1.253E-9
  • 1.928E-10
  • -0.002
  • 644.8
  • 0.415
  • 0.253
  • 2.37
  • 0
  • 0.223
  • 0.084
  • 0.028
  • -63.29

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
Maintenance
B2
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • 4.912E-7
  • 5.532E-12
  • 6.462E-12
  • 5.97E-11
  • 0
  • 2.971E-12
  • 2.729E-12
  • 2.384E-12
  • 5.303E-9
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • 0.000001081
  • 2.366E-10
  • 3.102E-10
  • 3.415E-9
  • 0
  • 1.271E-10
  • 2.763E-10
  • 2.628E-10
  • 9.791E-7
Incidence of disease due to PM emissions (PM) 2
  • 0.000003718
  • 1.539E-10
  • 1.242E-9
  • 1.52E-8
  • 0
  • 8.268E-11
  • 4.116E-10
  • 1.906E-10
  • -4.07E-7
Human exposure efficiency relative to U235 (IR) 1
  • 1.801
  • 0.0000637
  • 0.002
  • 0.005242
  • 0
  • 0.00003421
  • 0.0002809
  • 0.00003299
  • -0.236
Comparative toxic unit for ecosystems (ETP-fw) 2
  • 270.1
  • 0.294
  • 0.118
  • 0.606
  • 0
  • 0.158
  • 0.032
  • 0.016
  • -29.8
Soil quality index (SQP) 2
  • 189.3
  • 0.001
  • 0.068
  • 0.4612
  • 0
  • 0.0005727
  • 0.025
  • 0.006
  • -11.31