Close Collapse all sections
Process Data set: Fabric Tape (en) en de

Key Data Set Information
Location RER
Reference year 2024
Name
Fabric Tape
Use advice for data set Scope: This Environmental Product Declaration is an average EPD for dry adhesives covering the products: UZIN Sigaway Orginal, UZIN Sigaway Tape. The data provided in this EPD refers to the arithmetic mean of the products mentioned. All products covered by this EPD are manufactured at the Sifloor AG plant in Sursee, Switzerland. System boundary: Type of EPD: Cradle to gate with options, modules C1–C4, and module D (A1–A3 + C + D and additional modules). The additional modules are A4 and A5. The underlying LCA addresses all life cycle stages of the average product. The other life cycle stages are not relevant for the product class and no environmental impacts occur in these. The following activities are covered by the relevant modules: A1: Production of raw and auxiliary materials A2: Transport of raw and auxiliary materials to the plant A3: Production in the plant (incl. provision of energy and waste treatment) and the manufacture of the packaging A4: Transport of the packed product to the construction site A5: Installation of the product and disposal of the packaging and waste produced during installation (including the protective paper) C1: Manual removal of the product C2: Transport for disposal C3: As a worst-case scenario thermal treatment of the product in an incineration plant is modelled as end-of-life scenario C4: Not relevant because the product is incinerated (respective impacts declared in C3) D: Credits resulting from thermal utilisation of the product and packaging waste For the environmental impact, the use of green electricity was calculated taking into account the residual electricity mix for the remaining electricity. The proportion of the on-site electricity demand covered by green electricity in the total on-site electricity demand is 100 %.
Technical purpose of product or process The different fabric tapes are specially adapted to different substrates and floor coverings and are suitable for full-surface bonding of floor coverings. Substrates that meet the requirements of DIN 18365 are suitable for the use of dry adhesives after levelling.
Classification
Class name : Hierarchy level
  • OEKOBAU.DAT: 5.5.03 Beschichtungen / Innenbeschichtungen / Dispersionsklebstoffe
  • IBUCategories: 02 Building products / Construction adhesives and coatings / Dispersion adhesives and primers for floor coverings
General comment on data set This EPD comprises dry adhesives of the product category: Fabric-Tapes. All products considered here are based on the switchTec dry adhesive technology. This is a technology for floor bonding and fulfils the function of liquid adhesives as an alternative in flooring technology.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Material properties of the reference flow
    • layer thickness: 3.0E-4 m
    • grammage: 0.348 kg/m^2
Time representativeness
Data set valid until 2029
Technological representativeness
Technology description including background system The data set is representative for the production, use and disposal of dry adhesives of the category: Fabric Tapes in Europe. Within the manufacturing process, the components of the adhesive component are first added together according to the corresponding formula and mixed under continuous stirring. In two steps, the adhesive component is then first applied to the carrier material on one side and dried in the drying unit. The process is then repeated for the other side. Some substrates are such that the adhesive component penetrates the substrate. In this case, one coating cycle is sufficient and the second adhesive coating step is omitted. To prevent the dry adhesive from sticking to each other when rolled up, a protective paper (liner) is applied to one of the adhesive sides. Thermal utilisation was assumed for the end-of-life cycle. Factory-specific data was used for the production processes. For all other life cycle phases, data sets from Sphera Managed LCA Content (Content Version 2023.2) were used. The LCA model was created with the software LCA for Experts (version 10). Technical data: The various tapes are specially adapted to different substrates and floor coverings to comply with their requirements. Declared unit: This declaration is an average EPD and refers to 1 m2 of the fabric tapes UZIN Sigaway Orginal, UZIN Sigaway Tape and UZIN Pluratex, manufactured by SIFLOOR AG at the Sursee plant. All values stated in this EPD represent the arithmetic mean of the individual values of the products. The products mentioned are manufactured at the same plant, fulfil the same or a comparable function and differ only slightly in their formulation; other life cycle phases are the same, such as production. The declared unit of 1 m2 was chosen as the operating data is recorded either per linear metre [m] or per square metre [m2] and the sales unit is also given in m2. Using the conversion factor of the average mass per square metre, the data given can be related to 1 kg.

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Recycling Potential
D
Input
  • 4.632
  • 0.01396
  • 1.8
  • 0
  • 0.00046
  • 0.6242
  • -0.6061
Input
  • 2.376
  • 0
  • -1.782
  • 0
  • 0
  • -0.5938
  • 0
Input
  • 6.998
  • 0.01396
  • 0.02
  • 0
  • 0.00046
  • 0.02996
  • -0.6061
Input
  • 16.3
  • 0.1978
  • 0.3839
  • 0
  • 0.006516
  • 5.397
  • -2.119
Input
  • 5.569
  • 0
  • -0.3063
  • 0
  • 0
  • -5.263
  • 0
Input
  • 21.88
  • 0.1978
  • 0.07798
  • 0
  • 0.006516
  • 0.1403
  • -2.119
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.005861
  • 0.00001539
  • 0.0005294
  • 0
  • 5.069E-7
  • 0.0008194
  • -0.0004912
Output
  • 0.00005106
  • 7.32E-13
  • 2.61E-12
  • 0
  • 2.411E-14
  • 4.72E-12
  • -1.172E-10
Output
  • 0.04915
  • 0.00002851
  • 0.01778
  • 0
  • 9.392E-7
  • 0.03796
  • -0.001038
Output
  • 0.0003748
  • 2.558E-7
  • 0.000003513
  • 0
  • 8.425E-9
  • 0.000005846
  • -0.0001608
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0
  • 0
  • 0.2264
  • 0
  • 0
  • 0.3088
  • 0
Output
  • 0
  • 0
  • 0.4186
  • 0
  • 0
  • 0.5792
  • 0

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Recycling Potential
D
  • 0.7109
  • 0.01445
  • 0.1987
  • 0
  • 0.0004767
  • 0.2775
  • -0.1154
  • -0.2442
  • 0.00003322
  • 0.187
  • 0
  • 0.000001094
  • 0.1814
  • -0.0005193
  • 0.9465
  • 0.01429
  • 0.01166
  • 0
  • 0.0004712
  • 0.09611
  • -0.1149
  • 0.008591
  • 0.0001344
  • 0.000003689
  • 0
  • 0.000004427
  • 0.000005744
  • -0.00000743
  • 6.797E-9
  • 1.27E-15
  • 2.889E-14
  • 0
  • 4.185E-17
  • 5.048E-14
  • -8.877E-13
  • 0.002258
  • 0.0000454
  • 0.0000786
  • 0
  • 0.000001484
  • 0.0001472
  • -0.0001166
  • 0.002489
  • 0.00005033
  • 0.0000784
  • 0
  • 0.000001642
  • 0.0001451
  • -0.0001425
  • 0.007808
  • 0.0002609
  • 0.0003499
  • 0
  • 0.000008506
  • 0.0006433
  • -0.0004481
  • 0.000009261
  • 5.291E-8
  • 1.448E-8
  • 0
  • 1.743E-9
  • 2.802E-8
  • -1.832E-7
  • 0.0008247
  • 0.0000232
  • 0.00003007
  • 0
  • 7.573E-7
  • 0.00005639
  • -0.00004183
  • 0.134
  • 0.0001672
  • 0.02243
  • 0
  • 0.000005509
  • 0.03467
  • -0.01076
  • 0.000003012
  • 9.424E-10
  • 2.596E-10
  • 0
  • 3.105E-11
  • 4.355E-10
  • -8.133E-9
  • 21.84
  • 0.1973
  • 0.07754
  • 0
  • 0.0065
  • 0.1342
  • -2.119

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Comparative toxic unit for humans (carcinogenic) (HTP-c) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for humans (noncarcinogenic) (HTP-nc) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Incidence of disease due to PM emissions (PM) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Human exposure efficiency relative to U235 (IR) 1
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Comparative toxic unit for ecosystems (ETP-fw) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
Soil quality index (SQP) 2
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND
  • ND